Deployment Guide

OMNI vCenter integration
This information describes the OMNI vCenter integration to automate vCenter PortGroup VLANs.
vCenter VSS and DVS PortGroups
When you configure PortGroups of a virtual standard switch (VSS) with VLANs and distributed virtual switch (DVS) with VLANs on the
OMNI registered vCenter, the respective active and standby physical adapter interfaces are automatically configured by OMNI on the
SmartFabric ServerInterfaces. This is shown as tasks on the registered vCenter tasks pane.
NOTE: You cannot delete PortGroups on a VSS/DVS, or delete the VSS/DSS entirely as it clears all unused networks
from the SmartFabric ServerInterfaces.
DVS provides an option to change the VLAN of uplink
PortGroups. OMNI ignores PortGroup configuration if the VLAN type
PortGroup is set to VLAN trunking or private VLAN.
We recommend keeping the DVS uplink in Trunking mode and configure the virtual PortGroups with VLANs for each network. OMNI
configures the respective VLANs on the ToRs and SmartFabric uplinks.
OMNI automates the vCenter PortGroup VLAN and manages the registered vCenter by identifying the relation between the
SmartFabric ServerInterface and the ESXi host PNIC MAC.
NOTE:
When any server port is removed from an uplink on DVS/vDS, the VLAN association details stored on the
switches are not deleted. It is recommended to remove the network association configuration manually from the server
interface profile.
Identification of vCenter ESXi Host by OMNI
OMNI collects the PNIC MACs of all ESXi hosts in registered vCenters. If OMNI identifies the ServerInterface ID as a collected PNIC
MAC (Id=MAC without ':') of the host, OMNI identifies that host to belong to an OMNI registered SmartFabric instance.
Table 4. vCenter
PortGroup VLAN automation of identified ESXi host
vCenter action SmartFabric action by OMNI
Add/update PortGroup: VLAN of VSS/DVS Create network of PortGroup VLAN
Add network to SmartFabric ServerInterface
Remove PortGroup from VSS/DVS Remove unused networks from SmartFabric ServerInterface
NOTE: OMNI automation is not designed to delete unused ServerInterfaces of SmartFabric.
SmartFabric networks consolidation by OMNI
1. Collect all networks of registered SmartFabric.
2. Collect networks of ServerInterface of registered SmartFabric.
3. Identify SmartFabric networks created by the OMNI user interface, and SmartFabric networks that are not created by the OMNI user
interface.
4. Append networks that are not created by the OMNI user interface to SmartFabric uplink of 'Default'/'CreateOnly' type
5. Find unused networks; SmartFabric networks not created by the OMNI user interface, and not used by the SmartFabric
ServerInterface and SmartFabric uplinks.
6