Release Notes

Important Notes
To visit Dell TechCenter for accessing whitepapers, blogs, wiki-articles, videos, Product communities and forums, see: http://
en.community.dell.com/techcenter/systems-management/w/wiki/ 6277.dell-openmanage-plug-in-for-nagios-xi.
Known Issues and resolutions
Issue 1
Description: If a Dell Chassis is configured with only Internet Protocol Version 6 (IPv6) address and is not using the HTTPS
default port number (default 443) and was discovered using the Host Name, then the users will not be able to access
Chassis Management Controller (CMC) web interface from the Nagios XI console.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.
Resolution: If the default HTTPS port number (port 443) was changed, type https://[<CMC IPv6 address>]:<port
number> in the web browser, where <CMC IPv6 address> is the IPv6 address for CMC and <port number> is the
HTTPS port number. Please note that you must enclose the IPv6 address in the parenthesis([]).
Issue 2
Description: In "Dell Server Overall Health Status" service, Power Supply Roll up status would be shown as UNKNOWN even
if the actual Power supply Roll up status is OK after upgrading iDRAC firmware to 2.30.30.30 or a higher version when Dell
server is discovered using WS-MAN. The actual status will be shown correctly once there is any change in the health status
of the Power supply.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.
Resolution: Launch the respective iDRAC console for the Dell PowerEdge Server host from the Nagios XI to view the Power
Supply Roll up status.
Issue 3
Description: In "Dell Chassis I/O Module Status" service, value for "FabricType" is shown incorrectly as "UNKNOWN, for few
IO Modules when Dell PowerEdge M1000e chassis is discovered.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.
Resolution: Launch the respective chassis console for the Dell PowerEdge M1000e chassis host from the Nagios XI to view
the FabricType.
Issue 4
Description: In "Dell Chassis power supply status" service, health status for one of the power supply instance which is
standby is shown as "UNKNOWN" when Dell chassis is discovered.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI..
Resolution: Launch the respective chassis console for the Dell PowerEdge M1000e, Dell PowerEdge VRTX, and Dell
PowerEdge FX2/FX2s chassis host from the Nagios XI to view the health status of standby power supply.
Issue 5
Description: In "Dell Server Voltage Probe Status", service when one of the instance's actual status is UNKNOWN, that
instance will appear as CRITICAL instead of UNKNOWN while monitoring using SNMP protocol with iDRAC firmware version
lower than 2.30.30.30.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.
Resolution: Upgrade iDRAC firmware version to 2.30.30.30 or above.
Issue 6
Description: In "Dell Server Voltage Probe Status" service, some of the Voltage instances will be missing when Dell
PowerEdge C6320 server is discovered using WS-MAN protocol with iDRAC firmware version lower than 2.30.30.30.
Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.
Resolution: Upgrade iDRAC firmware version to 2.30.30.30 or above.
Issue 7
4