Users Guide

Switch Management Commands 2088
Examples
console#show power inline
Unit Status
===========
Unit........................................... 1
Power.......................................... On
Total Power.................................... 25 Watts
Threshold Power................................ 22 Watts
Consumed Power................................. 15 Watts
Usage Threshold................................ 90%
Power Management Mode.......................... Dynamic
Power Detection Mode........................... dot3at+legacy
High Availability Mode......................... enable
Port Configuration
==================
Port Powered Device State Priority Status Class Power[mW]
Detected/Assigned
----- -------------- ----- -------- ---------- ---------------- ---------
Gi1/0/1 auto Low On Class3/Class3 15800
Gi1/0/2 auto Low Test-Fail Unknown/Unknown
Gi1/0/3 auto Low Searching Unknown/Unknown
Gi1/0/4 auto Low Searching Unknown/Unknown
Gi1/0/5 auto Low Searching Unknown/Unknown
Gi1/0/6 auto Low Searching Unknown/Unknown
Gi1/0/7 auto Low Searching Unknown/Unknown
Gi1/0/8 auto Low Off Unknown/Unknown
console#show power inline gi1/0/1
Port Powered Device State Priority Status Class Power[mW]
Measured/Assigned)
---- -------------- ----- -------- ---------- ---------------- ---------
Gi1/0/1 auto Low Test-Fail Unknown/Unknown
Overload Counter............................... 0
Temperature The temperature as detected on the PoE chip (degrees
centigrade). If the reported temperature is greater than
205°C, the real temperature is 256°C—the reported
temperature.