Users Guide

Table Of Contents
Layer 2 Switching Commands 507
The EEE LPI history table entries
The Cumulative Power savings estimates
for a specified interface or for all the interfaces based upon the argument.
Syntax
clear green-mode statistics {
interface-id
| all}
interface-id
—An Ethernet interface identifier.
See
Interface Naming
Conventions
for interface representation.
all—All Ethernet interfaces.
Default Configuration
This command has no default configuration.
Command Mode
Privileged Exec
User Guidelines
This command has no user guidelines.
green-mode eee-lpi-history
Use the green-mode eee-lpi-history command in Global Configuration mode
to configure the Global EEE LPI history collection interval and buffer size.
Syntax
green-mode eee-lpi-history {sampling-interval
30 sec
36000 sec
| max-
samples
1
-
168
}
sampling-interval—The interval in seconds at which power consumption
data needs to be collected.
max-samples—Maximum number of samples to keep.
Default Configuration
The sampling-interval default value is 3600 seconds and the max-samples
default value is 168.