Deployment Guide
Table Of Contents
- Dell EMC PowerVault ME4 Series Storage System Deployment Guide
- Contents
- Before you begin
- Mount the enclosures in the rack
- Connect to the management network
- Cable host servers to the storage system
- Cabling considerations
- Connecting the enclosure to hosts
- Host connection
- Connect power cables and power on the storage system
- Perform system and storage setup
- Record storage system information
- Using guided setup
- Web browser requirements and setup
- Access the PowerVault Manager
- Update firmware
- Use guided setup in the PowerVault Manager Welcome panel
- Perform host setup
- Host system requirements
- Windows hosts
- Configuring a Windows host with FC HBAs
- Configuring a Windows host with iSCSI network adapters
- Configuring a Windows host with SAS HBAs
- Linux hosts
- Configuring a Linux host with FC HBAs
- Configure a Linux host with iSCSI network adapters
- Attach a Linux host with iSCSI network adapters to the storage system
- Assign IP addresses for each network adapter connecting to the iSCSI network
- Register the Linux host with iSCSI network adapters and create volumes
- Enable and configure DM Multipath on the Linux host with iSCSI network adapters
- Create a Linux file system on the volumes
- SAS host server configuration for Linux
- VMware ESXi hosts
- Fibre Channel host server configuration for VMware ESXi
- iSCSI host server configuration for VMware ESXi
- Attach an ESXi host with network adapters to the storage system
- Configure the VMware ESXi VMkernel
- Configure the software iSCSI adapter on the ESXi host
- Register an ESXi host with a configured software iSCSI adapter and create and map volumes
- Enable multipathing on an ESXi host with iSCSI volumes
- Volume rescan and datastore creation for an ESXi hosts with iSCSI network adapters
- SAS host server configuration for VMware ESXi
- Citrix XenServer hosts
- Fibre Channel host server configuration for Citrix XenServer
- iSCSI host server configuration for Citrix XenServer
- Attach a XenServer host with network adapters to the storage system
- Configure a software iSCSI adapter on a XenServer host
- Configure the iSCSI IQN on a XenServer host
- Enable Multipathing on a XenServer host
- Register a XenServer host with a software iSCSI adapter and create volumes
- Create a Storage Repository for a volume on a XenServer host with a software iSCSI adapter
- SAS host server configuration for Citrix XenServer
- Troubleshooting and problem solving
- Locate the service tag
- Operators (Ops) panel LEDs
- Initial start-up problems
- Cabling for replication
- SFP+ transceiver for FC/iSCSI ports
- System Information Worksheet
- Setting network port IP addresses using the CLI port and serial cable
This step isolates the problem to the external data path (SFP+ transceiver, host cable, and host-side devices) or to the
controller module port.
Is the host link status/link activity LED on?
● Yes – You now know that the SFP+ transceiver, host cable, and host-side devices are functioning properly. Return the
cable to the original port. If the link status LED remains off, you have isolated the fault to the controller module port.
Replace the controller module.
● No – Proceed to the next step.
7. Swap the SFP+ transceiver with the known good one.
Is the host link status/link activity LED on?
●
Yes – You have isolated the fault to the SFP+ transceiver. Replace the SFP+ transceiver.
● No – Proceed to the next step.
8. Reinsert the original SFP+ transceiver and swap the cable with a known good one.
Is the host link status/link activity LED on?
● Yes – You have isolated the fault to the cable. Replace the cable.
● No – Proceed to the next step.
9. Verify that the switch, if any, is operating properly. If possible, test with another port.
10. Verify that the HBA is fully seated, and that the PCI slot is powered on and operational.
11. Replace the HBA with a known good HBA, or move the host side cable and SFP+ transceiver to a known good HBA.
Is the host link status/link activity LED on?
● Yes – You have isolated the fault to the HBA. Replace the HBA.
● No – It is likely that the controller module needs to be replaced.
12. Move the cable and SFP+ transceiver back to its original port.
Is the host link status/link activity LED on?
● Yes – Monitor the connection for a period of time. It may be an intermittent problem, which can occur with damaged
SFP+ transceivers, cables, and HBAs.
● No – The controller module port has failed. Replace the controller module.
Host-side connection troubleshooting featuring 10Gbase-T and SAS host
ports
The following procedure applies to ME4 Series controller enclosures employing external connectors in the host interface ports.
The external connectors include 10Gbase-T connectors in iSCSI host ports and 12 Gb SFF-8644 connectors in the HD mini-SAS
host ports.
1. Halt all I/O to the storage system. See “Stopping I/O” in the Dell EMC PowerVault ME4 Series Storage System Owner’s
Manual.
2. Check the host activity LED.
If there is activity, stop all applications that access the storage system.
3. Check the Cache Status LED to verify that the controller cached data is flushed to the disk drives.
● Solid – Cache contains data yet to be written to the disk.
● Blinking – Cache data is being written to CompactFlash in the controller module.
● Flashing at 1/10 second on and 9/10 second off – Cache is being refreshed by the supercapacitor.
● Off – Cache is clean (no unwritten data).
4. Remove the host cable and inspect for damage.
5. Reseat the host cable.
Is the host link status LED on?
● Yes – Monitor the status to ensure that there is no intermittent error present. If the fault occurs again, clean the
connections to ensure that a dirty connector is not interfering with the data path.
● No – Proceed to the next step.
6. Move the host cable to a port with a known good link status.
This step isolates the problem to the external data path (host cable and host-side devices) or to the controller module port.
Is the host link status LED on?
Troubleshooting and problem solving