Owners Manual

Table 27. Event descriptions and recommended actions (continued)
Number Severity Description/Recommended actions
268 Info. A volume-copy operation for the indicated volume has completed.
Recommended actions:
No action is required.
269 Error A partner firmware update operation could not be performed.
This event has these variants:
1. System health is insufficient to support firmware partner update.
2. System has unwritable cache data present.
3. Unable to determine if unwritable cache data is present.
4. Incompatible firmware versions in the controller modules.
5. Incompatible firmware is present in the system.
Recommended actions:
For variant 1, 2, or 3: You must resolve this condition before the firmware update will
proceed. Log into the system and run the show system command to identify unhealthy
components and find recommendations for restoring system health. The check
firmware-upgrade-health command can be used to verify that the system is ready for
firmware upgrade. For unwritten cache data, use the CLI show unwritable-cache
command.
For variant 4: This feature can be manually re-enabled after both controller modules are
running compatible firmware.
For variant 5: The controller modules should be updated to the latest version of firmware.
Info. A partner firmware update operation has started. This operation is used to copy firmware from
one controller to the other to bring both controllers up to the same version of firmware.
Recommended actions:
No action is required.
270 Warning Either there was a problem reading or writing the persistent IP data from the FRU ID SEEPROM,
or invalid data were read from the FRU ID SEEPROM.
Recommended actions:
Check the IP settings (including iSCSI host-port IP settings for an iSCSI system), and update
them if they are incorrect.
271 Info. The storage system could not get a valid serial number from the FRU ID SEEPROM on the
controller, either because it could not read the FRU ID data, or because the data in it is not valid
or has not been programmed. Therefore, the MAC address is derived by using the controller
serial number from flash. This event is only logged one time during bootup.
Recommended actions:
No action is required.
272 Info. A snap pool was expanded due to a policy trigger.
Recommended actions:
No action is required.
273 Info. PHY fault isolation has been enabled or disabled by a user for the indicated enclosure and
controller module.
Recommended actions:
No action is required.
274 Warning The indicated PHY has been disabled, either automatically or by a user. Drive PHYs are
automatically disabled for empty disk slots or if a problem is detected. The following reasons
indicate a likely hardware fault:
Events and event messages 103