Table 33. Known hardware and configuration issues
Issue Description
50686 Running a rescan using ME Storage Manager causes a temporary false temp sensor error.
Workaround: This health issue resolves itself and does not generate an event in the logs.
NOTE: This issue is fixed in GT280R004-01 firmware.
50685 ME Storage Manager validation fails on SMTP server if you enter an FQDN instead of an IP.
Workaround: Enter a valid IP address, or use the CLI.
NOTE: This issue is fixed in GT280R004-01 firmware.
50204 Rarely, replacing a controller with DHCP turned off causes the Storage Controller to have an invalid IPv6 IP
address.
Workaround: Do the following from the controller that was not replaced:
1. Add the IPv6 address.
2. Set the correct IPv4 network parameters.
3. In the CLI run restart mc <ID> where <ID> is the replaced controller. For example, to restart
controller B, run restart mc b.
NOTE: This issue is fixed in GT280R004-01 firmware.
49874 A controller module was killed by its partner.
Workaround: Restart the controller module.
NOTE: This issue is fixed in GT280R004-01 firmware.
49932 After attempting to change FDE keys twice on a failed disk, the system secured the disks.
Workaround: Remove failed disks from the system, and replace them with new ones.
NOTE: This issue is fixed in GT280R004-01 firmware.
48310 ME Storage Manager returns an error if you click Turn OFF LEDs without selecting any component.
Workaround: You can click OK and ignore the error, or select a component with LEDs on and click Turn
OFF LEDs.
NOTE: This issue is fixed in GT280R004-01 firmware.
Table 34. Known installation and update issues
Issue Description
50418 Inserting a controller containing older firmware causes the controller with newer firmware to unexpectedly
reboot after the firmware is synchronized.
Workaround: None needed. The automatic reboot fixes the issue.
NOTE: This issue is fixed in GT280R004-01 firmware.
50140 In rare cases, after installing a firmware bundle, event 235 is logged with details that include Not Ready,
enclosure services unavailable.
Workaround: Quiesce I/O to the storage system and then power cycle the controller enclosure.
49945 Network IP settings of a newly inserted controller are incorrect if the following are true:
The newly inserted controller uses IPv6 addressing.
The mid-plane is set to static IP addressing.