CLI Guide

Table Of Contents
illegal: Sends a reply that there is a LUN but that the request is illegal. Sense data returned
is sensekey = 5, code = 25h, qualifier = 0. If the system is used in a VMware environment, use this
option.
partner-firmware-upgrade enabled|disabled|on|off
Optional. Sets whether component firmware versions are monitored and will be automatically updated
on the partner controller.
disabled or off: Partner firmware upgrade is disabled.
enabled or on: Partner firmware upgrade is enabled. This is the default.
partner-notify enabled|disabled|on|off
Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this
option to have the partner also change to write-through mode for better data protection. Disable this
option to allow the partner to continue using its current caching mode for better performance.
Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this
option to have the partner also change to write-through mode for better data protection. Disable this
option to allow the partner continue using its current caching mode for better performance.
disabled or off:Notification is disabled. This is the default
enabled or on:Notification is enabled.
power-supply-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a power supply
fails.
disabled or off:The power-supply failure trigger is disabled. This is the default.
enabled or on:The power-supply failure trigger is enabled.
restart-on-capi-fail enabled|disabled|on|off
Optional. Sets whether a Storage Controller that experiences a CAPI hang will be forced to restart.
This is disabled by default. A CAPI hang is perceived as a management-interface hang. As part of the
restart process, a dump file is created and event 107 is logged. To provide the dump file to technical
support for debugging, use the Save Logs action in the PowerVault Manager.
single-controller
For use by a service technician only.
Optional. For a system that lacks a second controller module for redundancy and is intended to
be used as a single-controller system, this parameter changes the operating/redundancy mode to
Single Controller. This prevents the system from reporting the absent partner controller as an error
condition. This parameter does not affect any other system settings. Installing a second, functional
controller module will change the mode to Active-Active ULP.
smart enabled|disabled|on|off|detect-only
Optional. Enables or disables SMART (Self-Monitoring Analysis and Reporting Technology) monitoring
for all disks in the storage system. When SMART is enabled, the system checks for SMART events
one minute after a restart and every five minutes thereafter. SMART events are recorded in the
event log.
disabled or off:Disables SMART for all disks in the system and for all disks added to the
system.
enabled or on:Enables SMART for all disks in the system and for all disks added to the system.
This is the default.
detect-only: Detects but does not change the SMART setting of each disk in the system, and
for each new disk added to the system.
spin-down enabled|disabled|on|off
Optional. Sets whether spinning disks that are available or are global spares will spin down after a
period of inactivity shown by the spin-down-delay parameter.
disabled or off:Drive spin down for available disks and global spares is disabled. This is the
default. Disabling spin down will set the spin-down delay to 0.
enabled or on:Drive spin down for available disks and global spares is enabled. If the spin-down-
delay parameter is not specified, the delay will be set to 60 minutes.
Alphabetical list of commands
111