CLI Guide

Table Of Contents
Table 7. advanced-settings-table properties (continued)
Name Type Description
missing-lun-response-numeric uint32 Numeric equivalents for missing-lun-response values.
0: Not Ready
1: Illegal Request
controller-failure string Shows whether the cache policy will change from write-back to write-through
when a controller fails.
Disabled: The controller failure trigger is disabled.
Enabled: The controller failure trigger is enabled.
controller-failure-numeric uint32 Numeric equivalents for controller-failure values.
0: Disabled
1: Enabled
super-cap-failure string Shows whether the cache policy will change from write-back to write-through
when the supercapacitor that provides backup power for cache is not fully
charged or fails.
Disabled: The supercapacitor failure trigger is disabled.
Enabled: The supercapacitor failure trigger is enabled.
super-cap-failure-numeric uint32 Numeric equivalents for super-cap-failure values.
0: Disabled
1: Enabled
compact-flash-failure string Shows whether the cache policy will change from write-back to write-through
when CompactFlash memory is not detected during POST (Power-On Self-Test),
fails during POST, or fails during controller operation.
Disabled: The CompactFlash failure trigger is disabled.
Enabled: The CompactFlash failure trigger is enabled.
compact-flash-failure-numeric uint32 Numeric equivalents for compact-flash-failure values.
0: Disabled
1: Enabled
power-supply-failure string Shows whether the cache policy will change from write-back to write-through
when a power supply fails.
Disabled: The power-supply failure trigger is disabled.
Enabled: The power-supply failure trigger is enabled.
power-supply-failure-numeric uint32 Numeric equivalents for power-supply-failure values.
0: Disabled
1: Enabled
fan-failure string Shows whether the cache policy will change from write-back to write-through
when a fan fails.
Disabled: The fan failure trigger is disabled.
Enabled: The fan failure trigger is enabled.
fan-failure-numeric uint32 Numeric equivalents for fan-failure values.
0: Disabled
1: Enabled
temperature-exceeded string Shows whether the system will shut down a controller when its temperature
exceeds the critical operating range.
Disabled: The over-temperature trigger is disabled.
Enabled: The over-temperature trigger is enabled.
temperature-exceeded-
numeric
uint32 Numeric equivalents for temperature-exceeded values.
0: Disabled
1: Enabled
API basetype properties 289