CLI Guide

Table Of Contents
One or more temperature sensors indicate a critical temperature. Code
load failure
At least one controller contains unwritten cache data. Data corruption,
data loss
One or more supercapacitors have failed. Code load failure
One or more power supplies are not functioning. Code load failure
One or more fans are not functioning. Code load failure
One or vdisks are in a quarantied state. Code load failure
Basetypes
code-load-readiness
code-load-readiness-reason
status
See also
show controllers
show disk-groups
show disks
show enclosures
show fans
show power-supplies
show sensor-status
show system
show vdisks
check support-assist
Description
Checks the connection from the storage system to the SupportAssist server.
Minimum role manage
Syntax
check support-assist
Output A message specifies whether the storage system can connect to the SupportAssist server and
transmit data to it.
Examples Check the connection from the storage system to the SupportAssist server.
# check support-assist
See also
send support-assist-logs
set support-assist
set support-assist-info
show support-assist
clear cache
Description
Clears unwritable cache data from both controllers.
NOTE: If you are uncertain whether to use this command, contact technical support for
assistance.
This data cannot be written to disk because it is associated with a volume that no longer exists or
whose disks are not online. If the data is needed, the volume's disks must be brought online. If the
Alphabetical list of commands 39