CLI Guide

Table Of Contents
Table 104. sensors properties (continued)
Name Type Description
B : Controller B.
both : Both controllers.
N/A
controller-id-numeric uint32 Numeric equivalents for controller-id values.
0: B
1: A
2: both
N/A
sensor-name string Sensor name and location.
value string
For a sensor, its value.
For overall unit status, one of the status values below.
status string
OK : The sensor is present and detects no error condition.
Warning : The sensor detected a non-critical error condition. Temperature,
voltage, or current is between the warning and critical thresholds.
Critical : The sensor detected a critical error condition. Temperature,
voltage, or current exceeds the critical threshold.
Unavailable : The sensor is present with no known errors, but has not
been turned on or set into operation because it is initializing. This typically
occurs during controller startup.
Unrecoverable : The enclosure management processor (EMP) cannot
communicate with the sensor.
Unknown : The sensor is present but status is not available.
Not Installed : The sensor is not present.
Unsupported : Status detection is not implemented.
status-numeric uint32 Numeric equivalents for status values.
0: Unsupported
1: OK
2: Critical
3: Warning
4: Unrecoverable
5: Not Installed
6: Unknown
7: Unavailable
sensor-location uint32 Superseded by the container property.
container string Hardware component that contains the sensor.
controllers
enclosures
fan
iom
midplane
power-supplies
container-numeric uint32 Numeric equivalents for container values.
17: enclosures
18: midplane
19: controllers
20: iom
21: power-supplies
22: fan
394 API basetype properties