Release Notes

Known issues in GT280R008-01 firmware
The following are known issues in GT280R008-01 firmware:
Table 19. Known installation and update issues
Issue Description Workaround
50140 In rare cases, after installing a firmware bundle, event 235 is
logged with details that include Not Ready, enclosure
services unavailable.
Quiesce I/O to the storage system and then power
cycle the controller enclosure
Table 20. Known storage management issues
Issue Description Workaround
51833 Performance issues with 10Gbase-T controllers and Intel
Ethernet Converged Network Adapter X520.
Update to the latest version of the Intel Ethernet
Converged Network Adapter X520 driver. Then,
disable the interrupts in the Intel Ethernet
Converged Network Adapter X520 driver.
49962 PowerVault Manager panels use inconsistent terms for SAS
disks:
MDL and SAS MDL are spinning midline or nearline SAS
disks.
SSD and sSAS are SAS SSDs.
None.
49055 SLP for IPv6 and DNS is not supported. None.
12 GT280R008-01 Firmware