Dell EMC SD-WAN Edge 600 Series Installation Guide Abstract The Dell EMC SD-WAN Edge 600 Series Installation Guide provides site preparation recommendations, step-by-step procedures for installing your device, and connecting to a power source. Dell EMC Networking February 2021 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents Chapter 1: About this guide........................................................................................................... 5 Related documents............................................................................................................................................................. 6 Information symbols............................................................................................................................................................
Taiwan............................................................................................................................................................................ 30 Singapore certification of compliance.................................................................................................................... 30 Ukraine certification of compliance........................................................................................................................
1 About this guide This guide provides site preparation recommendations, step-by-step procedures for installing your device, and connecting to a power source. CAUTION: To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this equipment. WARNING: Only trained and qualified personnel can install this equipment. Read this guide before you install and power up this equipment. This equipment contains two power cables. Disconnect both power cables before servicing.
Related documents For more information about the Dell EMC SD-WAN Edge 600 Series, see the following documents: ● Dell EMC SD-WAN Edge 600 Series Quick Start Guide ● Dell EMC SD-WAN Edge 600 Series Release Notes NOTE: For the most recent documentation, see the Dell EMC support site at www.dell.com/support. Information symbols This book uses the following information symbols: NOTE: The Note icon signals important operational information.
2 Dell EMC SD-WAN Edge 600 Series The Dell EMC SD-WAN Edge 600 Series (610, 620, 640, and 680) simplifies SD-WAN integration into your IT solution. It connects the service provider edge or small-to-medium branch locations to the cloud to host virtual network functions. The Edge 600 Series with 10/30/50/100/200/500 Mbps and 1/5/10 Gbps comes with VMware software preinstalled. ● VMware SD-WAN Edge—a hardware device with VMware software preinstalled.
Figure 3. Dell EMC SD-WAN Edge 600 series system (back) 1. 2. 3. 4. 5. 6. Mini-USB 2.0 (Edge 610) or Micro-USB 2.0 console port ( Edge 620, Edge 640, and Edge 680) Reset button SFP/SFP+ ports Two 1 GbE GE1/GE2 default LAN connections Four 1 GbE GE3-6 or SFP1-2 default WAN connections DC Power connection The Edge 600 series includes two USB 3.0 Type-A ports on the right and left sides of the platform. Figure 4. USB 3.
○ Edge 640 and Edge 680 — 240 GB SSD ● DDR4 with ECC ● Memory by SKU: ○ Edge 610 — 4 GB on board ○ Edge 620 — 8 GB on board ○ Edge 640 and Edge 680 — 16 GB on board + 16 GB SO-DIMM ● Zero, one, or two fans with airflow from the sides and back of the platform ● External power supply 1 ● Desktop mount with rubber feet and wall mount accessories included ● Optional rack mount accessory available Physical dimensions ● 8.1 in x 7.9 in x 2.0 in (W x D x H) ● 20.8 cm x 20.0 cm x 5.
2. 1 GbE networking LAN and WAN port LEDs Table 2. SFP/SFP+ port status indicator LEDs Description Status Link and speed Left side Solid green (bicolor green Solid green and amber): Link up, 10 Gbps (for SFP+) Solid amber Link up, 100 Mbps (for SFP) Solid amber Link up, 1 Gbps (for SFP+) Off Link down Off No activity Blinking green Activity Right side (green): Link up, 1 Gbps (for SFP) Table 3.
Table 4. Edge 600 series configurations (continued) Model Edge 680 Configurations ● ● ● ● ● ● ● ● Two 10 GbE SFP+ ports One Micro-USB 2.0 console port Two USB 3.0 Type-A ports AC power supply Two fans Airflow on sides and back 32 GB DDR4 memory 240 GB SSD ● ● ● ● ● ● ● ● ● ● 16-core CPU Six 1 GbE Ethernet ports Two 10 GbE SFP+ ports One Micro-USB 2.0 console port Two USB 3.
3 Site preparations The Edge 600 Series platform connects the service provider edge or small-to-medium branch locations to the cloud, to host virtual network functions. Use the platform on a desktop or optionally install the platform in a wall or rack. NOTE: If you optionally install the platform into a rack or cabinet, install the platform first, and then install any additional components such as cables or optics.
Fans and airflow Fan installation is done at the factory. The Edge 600 series supports forced airflow from the sides and back of the enclosure. ● 2-core—no fan ● 4-core—single fan ● 8-core—two fans ● 16-core—two fans Position the platform in a well-ventilated environment with clearance around the exhaust vents. The fan speed varies based on internal temperature monitoring. The platform never intentionally turns off the fans. NOTE: The Edge 600 series fans are not field-replaceable.
4 Edge 600 Series installation To install the Edge 600 Series platform, complete the installation procedures in the order that is presented in this chapter. Always handle the platform and components with care. NOTE: For thermal considerations, do not stack the Edge 600 Series platforms on top of each other. NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the platform and components.
Wall mount installation Prerequisites The Edge 600 series platform includes wall mount installation hardware. You need a torque screwdriver to complete this installation. About this task WARNING: When mounting the Edge 600 series unit to the wall, face the Ethernet ports up towards the ceiling and the system status LED panel down, facing the floor. NOTE: When driving the screws into the bracket and platform, verify that you torque to 5 lb-in.
2. To mount the Edge 600 series unit to the wall using the wall mount bracket provided, you must first anchor the screws into the wall surface. Depending on the type of wall surface, use the M3 screw and anchor to ensure a secure installation. The recommended M3 screw dimensions are as follows: Figure 7.
Figure 8. M3 screw installation points 4. After the brackets have been attached to the Edge 600 series unit and the screws are mounted into the wall, place the brackets over the screws and slide the unit to one side to secure the unit in place. Figure 9. Wall mount bracket installation Rack mount Prerequisites As an option, you can mount the Edge 600 Series platform to a dual rack mount tray. Purchase the dual rack mount tray separately. You must have a torque screwdriver to complete this installation.
About this task NOTE: When driving the screws into the bracket and platform, verify that you torque to 5 lb-in. NOTE: When mounting the platform to the dual rack mount tray, remove the rubber pads from the bottom of the platform. NOTE: Ensure the platform is in a well-ventilated environment with clearance around the exhaust vents. Steps 1. Place one or two Edge 600 Series platforms in the dual rack mount tray. 2. Use the eight included M3 screws to attach the platforms to the dual rack mount tray.
● Optional: The equipment rack is properly mounted and grounded. ● The ambient temperature around the platform, which may be higher than the room temperature, is within the limits that are specified for the Edge 600 Series. For more information, see Specifications. ● There is no source of heat near the unit. NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the platform and components.
Figure 11. Edge 600 series DC power connection port 2. Connect the power adapter to the AC power outlet. When the Edge powers ON, verify that the status LED on the front of the Edge system is on. NOTE: Connect the device to a properly wired earth-ground AC power outlet. 3. Connect one of the default WAN ports (SFP1,SFP2 or GE3, GE4, GE5, or GE6) to an available Internet connection. NOTE: SFP modules are not included. Figure 12. Edge 600 series SFP/SFP+ ports, and ports GE3 through GE6 a.
Figure 14. Edge 600 series default LAN ports GE1 and GE2 Next steps After following these instructions, if you are still unable to activate the Edge, contact your Dell EMC sales representative.
5 User interface You can activate and troubleshoot basic functionality of the Edge 600 series by connecting your laptop or mobile device using one of the default LAN ports (GE1 or GE2) or through the Wi-Fi connection. For additional information about initial activation, activation steps, or how to troubleshoot basic functionality of the Dell EMC Edge 600 series of systems, see the Advanced Activation Guide for your system: Table 5.
6 Specifications This section lists the Edge 600 Series specifications. NOTE: For RoHS information, see Restricted Material Compliance. Topics: • • • • • Chassis physical design IEEE standards Safety standards and compliance agency certifications Agency compliance Product recycling and disposal Chassis physical design Table 6. Edge 600 Series specifications Feature Specification Size 8.1 in x 7.9 in x 2.0 in (W x D x H) 20.8 cm x 20.0 cm x 5.
Table 7. Edge 600 Series temperatures (continued) Feature Specification Storage relative humidity 5% to 90% (RH) Operating altitude Maximum: 10,000 feet (3,048 meters) No performance degradation up to 3,117 feet (950 meters) IEEE standards The Edge 600 Series complies with the following IEEE standards: ● ● ● ● 802.1ab—LLDP 802.1ax—Layer 2 802.1d, 802.1w, 802.1s, 802.1x—Mgmt/Security; 802.3x—Layer 2 802.
Consult the dealer or an experienced radio/TV technician for help. FCC caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation exposure statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
Avertissement: 1. Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux; 2. Les pires angles d’inclinaison nécessaires pour rester conforme à l’exigence de la p.i.r.e. applicable au masque d’élévation, et énoncée à la section 6.2.2 3), doivent être clairement indiqués. 3.
Brazilian certificate European Union EU Declaration of Conformity Declaration #550004 for Velocloud Edge Wireless Gateway Model: Edge510 Manufactured by: Velocloud Networks, Inc.
The CE testing and RED GAP analysis was performed by a third party test lab, Compatible Electronics, Inc.,.Lake Forest, CA. The report number is D70829Q1. Signed for and on behalf of: Velocloud Networks, Inc. Date: 4/16/2019 Place of issue: 3401 Hillview Ave Palo Alto, CA 94034 Signed By: Robert Bortolotto Title: Sr. Director of Engineering Signature: Japan VCCI compliance for class A equipment Figure 15.
BTE compliance certificate Japanese BTE compliance certificate Korean certification of compliance Korean certification of compliance Figure 17. Korean package label Radio compliance certificate Korea (Korean warning statement is only required for devices contain 2400~2483 and/or 5725~5825 MHz radios) 해당 무선설비는 운용 중 전파혼신 가능성이 있음 Korean radio compliance certificate Mexico Mexican compliance. La operación de este equipo está sujeta a las siguientes dos condiciones: 1.
Taiwan Taiwanese certification of compliance 台灣: 國家通訊傳播委員會 低功率電波輻射性電機管理辦法 第十二條經型式認證合格之低功率射頻電機,非經許可,公司、商號 或使 用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 第十四條低功率射頻電機之使用不得影響飛航安全及干 擾合法通信;經發 現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。 前項合法通信,指依電信法規定作業之 無 線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 在 5.25-5.35 秭赫頻帶內操作 之無線資訊傳輸設備,限於室內使用 Singapore certification of compliance Singaporean radio compliance. Complies with IMDA Standards XXXXXX (xxxxxx = Dealer Code) Certification pending.
Figure 18. The European WEEE symbol In accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is to be collected separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the WEEE Directive, as shown above, must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to customers for the return, recycling and recovery of WEEE.
7 Dell EMC support The Dell EMC support site provides documents and tools to help you effectively use Dell EMC equipment and mitigate network outages. Through the support site you can obtain technical information, access software upgrades and patches, download available management software, and manage your open cases. The Dell EMC support site provides integrated, secure access to these services. To access the Dell EMC support site, go to www.dell.com/support/.