Storage 40° to 65°C (40° to 149°F) at a maximum altitude of 12,000 m
(39,370 ft)
Fresh Air For information on fresh air, see Expanded Operating Temperature
section.
Maximum temperature gradient (operating and
storage)
20°C/h (68°F/h)
Relative humidity
Operating 10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point
Storage 5% to 95% (noncondensing) with 33°C (91°F) maximum dew point
Maximum vibration
Operating 0.26 G
rms
at 5350 Hz (all operation orientation)
Storage 1.88 G
rms
at 10500 Hz for 15 min (all six sides tested)
Maximum shock
Operating Six consecutively executed shock pulses in the positive and negative x, y,
and z axes of 40 G for up to 2.3 ms
Storage Six consecutively executed shock pulses in the positive and negative x, y,
and z axes (one pulse on each side of the system) of 71 G for up to 2 ms
Altitude
Operating 3,048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Operating temperature de-rating
Up to 35 °C (95 °F) Maximum temperature is reduced by 1°C/300 m (33.8°F/984.25 ft)
above 950 m (3,117 ft)
35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1°C/175 m (1°F/574.14 ft) above
950 m (3,117 ft).
40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1°C/125 m (1°F/410.1 ft) above 950
m (3,117 ft)
Expanded operating temperature
Expanded operating temperature
Specifications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to
35°C), the system can operate continuously in temperatures as low
as 5°C and as high as 40°C.
For temperatures between 35°C to 40°C, de-rate maximum allowable
temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
1% of annual operating hours 5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to
35°C), the system can operate down to 5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum
allowable temperature by 1°C per 125 m above 950 m (1°F per 228
ft).
NOTE: When operating in the expanded temperature range, system performance may be impacted.
18 Technical specifications