Owners Manual

Maximum shock specications
Table 16. Maximum shock specications
Maximum shock Specications
Operating 24 executed shock pulses 6 G in the positive and negative x, y, z
axis for up to 11 ms (four pulses on each side of the system).
Storage Six consecutively executed shock pulses of 71 G in the positive and
negative x, y, z axes for up to 2 ms (one pulse on each side of the
system).
Maximum altitude specications
Table 17. Maximum altitude specications
Maximum altitude Specications
Operating 3048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Operating temperature de-rating specications
Table 18. Operating temperature
Operating temperature de-rating Specications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft)
above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above
950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228
Technical specications 17