CLI Guide
Table 58. Details of gettracelog (continued)
Output
The default output display shows the record number, timestamp, source and description. The timestamp
begins at midnight, January 1 and increases until the system starts. After the system starts, the system’s
timestamp is used.
Example
● Display entire log
racadm gettracelog
● Display number of records in log
racadm gettracelog -i
Total Records: 228
getversion
Table 59. Details of getversion
Description Displays the current software version, model and generation information, and whether the target device
can be updated.
Synopsis
● racadm getversion
● racadm getversion [-b | -c | —i]
● racadm getversion [-f <filter>]
Input
● -c — Displays the server's current CPLD version.
● -b — Displays the server's current BIOS version.
● -i — Displays the server's current IDSDM version.
● -f <filter> — Filters the components and must be one of the following values:
○ bios: BIOS
○ idrac: iDRAC
○ lc: Lifecycle Controller
○ idsdm: SD card
racadm getversion -c
Table 60. Details of
racadm getversion -c
<
Server
> <
CPLD Version
> <
Blade Type
>
server-1 1.0.5 PowerEdgeM520
server-2 1.0.3 PowerEdgeM610x
server-4 1.0.0 PowerEdgeM710HD
server-5 1.0.3 PowerEdgeM710
server-7 1.0.6 PowerEdgeM620
RACADM Subcommand Details 63