Users Guide
Table Of Contents
- Lifecycle Controller ユーザーズガイド
- はじめに
- Lifecycle Controller の使用
- オペレーティングシステムの導入
- 監視
- ファームウェアアップデート
- Configure
- 保守
- 使いやすいシステムコンポーネント名
- セットアップユーティリティとブートマネージャの使用
- トラブルシューティングとよくあるお問い合わせ(FAQ)
Selecting physical disks
Use the Select Physical Disks screen to select the physical disks to be used for the virtual drive and select the physical disk drive-related
properties.
The number of physical disks required for the virtual disk varies depending on the RAID level. The minimum and maximum numbers of
physical disks required for the RAID level are displayed on the screen.
● Protocol — Select the protocol for the disk pool: Serial Attached SCSI (SAS), Serial ATA (SATA), or NVM Express (NVMe). SAS
drives are used for high performance, while SATA drives are used for a more cost-effective solution. A disk pool is a logical grouping of
physical disk drives on which one or more virtual drives can be created. The protocol is the type of technology used to implement
RAID.
● Media Type — Select the media type for the disk pool: Hard Disk Drives (HDD) or Solid State Disks (SSD). HDDs use traditional
rotational magnetic media for data storage and SSDs implement flash memory for data storage.
● Disk Boot Size — Select one of the following disk block sizes:
○ 512 — indicates that the 512 bytes block size hard drives (HDD) are selected.
○ 4K — indicates that the 4K block size hard disk drives (HDD) are selected. 4K block HDDs allow the faster data transfer with
fewer commands.
● T10 Protection Information (T10 PI) Capability— It is known as DIF (Data Integrity Fields) and the supporting HDDs are referred to DIF
drives. The T10 enabled HDDs validates and stores the data integrity fields for each block. It performs this action when you write the
data on the disk and return these values on a read request. When you read or write the data from the HDD, the data is checked for
the errors. Select one of the following types of T10 protection information capabilities:
○ All — indicates that both the T10 PI capable and non-capable HDDs are selected.
○ T10 PI Capable — indicates that only T10 PI capable HDDs are selected.
○ Non-T10 Capable — indicates that only non-T10 capable HDDs are selected.
NOTE: PERC 9 with version 9.3.2 and above doesn’t support T10 PI capabilities.
● Encryption Capability — Select Yes to enable encryption capability.
● Encryption Protocol — Select the type of encryption protocol. Select one of the following types of encryption protocol type:
○ TCG Enterprise SSC — indicates only TCG Enterprise SSC Capable drives are selected.
○ TCG Opal SSC — indicates only TCG Opal SSC Capable drives are selected.
○ Non-Encryption Capable — indicates only non-encryption capable drives are selected.
● Select Span Length — Select the span length. The span length value refers to the number of physical disk drives included in each
span. Span length applies only to RAID 10, RAID 50, and RAID 60. The Select Span Length — Setting span length is only supported in
RAID 10, RAID 50, and RAID 60. And in a RAID 10 configuration, the default value is set to 2 and the option Span Length is not available
is the storage controller supports Uneven span.
● Select the physical disk-drives using the check boxes at the bottom of the screen. The physical disk-drive selection must meet the
requirements of the RAID level and span length. To select all the physical disk-drives, click Select All. After you select the option, the
option changes to Deselect.
仮想ディスク属性の設定
このページを使用して、次の仮想ドライブ属性の値を指定してください。
● [サイズ] — 仮想ドライブのサイズを指定します。
● [ストライプエレメントサイズ] — ストライプエレメントのサイズを選択します。ストライプエレメントサイズは、ストライ
プされている各物理ドライブでストライプが使用するドライブ容量です。[ストライプエレメントサイズ]リストには、画面に
最初に表示されたオプションより多くのオプションが表示される場合があります。すべてのオプションを表示するには、上下
矢印を使用します。
● [読み取りポリシー] — 読み取りポリシーを選択します。
○ [先読み] — コントローラはデータシーク時に仮想ドライブのシーケンシャルセクタを読み取ります。データが論理ドライ
ブのシーケンシャルセクタに書き込まれている場合は、先読みポリシーによってシステムのパフォーマンスが向上する可能
性があります。
○ [先読みなし] — コントローラは先読みポリシーを使用しません。データがシーケンシャルセクタではなくランダムに書き
込まれている場合は、先読みなしポリシーによってシステムのパフォーマンスが向上する可能性があります。
○ [適応先読み] — 最新の読み取り要求でドライブのシーケンシャルセクタにアクセスした場合にのみ、先読みポリシーが使
用されます。最新の読み取り要求でドライブのランダムセクタにアクセスした場合は、先読みなしポリシーが使用されま
す。
● [書き込みポリシー] — 書き込みポリシーを選択します。
44 Configure