CLI Guide

The following command provides the list of enclosures:
racadm storage get enclosures
Enclosure.Internal.0-1:RAID.Integrated.1-1\
Enclosure.Internal.0-1:PCIeExtender.Slot.3
The following command provides the properties of the specified PCIeSSD enclosure:
racadm storage get enclosures:Enclosure.Internal.0-1:PCIeExtender.Slot.3
Enclosure.Internal.0-1:PCIeExtender.Slot.3
RollupStatus = Ok
DeviceDescription = Enclosure.Internal.0-1:PCIeExtender.Slot.3
Name = PCIe SSD BP 1
SlotCount = 4
FirmwareVersion = 0.80
PcieSSDBusId = 182
PcieSSDDeviceId = 0
PcieSSDFunctionId = 0
To get the list of physical disks and properties of the specified PCIeSSD physical disk.
The following command provides the list of physical disks:
racadm storage get pdisks
Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1
Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1
Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1
Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1
Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1
Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1
Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
Disk.Bay.6:Enclosure.Internal.0-1:PCIeExtender.Slot.3
Disk.Bay.7:Enclosure.Internal.0-1:PCIeExtender.Slot.3
Disk.Bay.9:Enclosure.Internal.0-1:PCIeExtender.Slot.3
The following command provides the properties of the specified PCIe SSD physical disk as a member of SW RAID:
racadm storage get pdisks:Disk.Bay.0:Enclosure.Internal.0-1
Disk.Bay.0:Enclosure.Internal.0-1
Status = Ok
DeviceDescription = PCIe SSD in Slot 0 in Bay 1
Name = PCIe SSD in Slot 0 in Bay 1
State = Ready
Size = 931.250 GB
BusProtocol = NVMe
MediaType = SSD
Model = Dell Express Flash NVMe P4510 1TB SFF
ProductId = a54
SerialNumber = PHLJ9106019V1P0FGN
DeviceProtocol = NVMe-MI1.0
Manufacturer = Intel
PCIeNegotiatedLinkWidth = x2
PCIeCapableLinkWidth = x4
MaxCapableSpeed = 8 GT/s
NegotiatedSpeed = 8 GT/s
FormFactor = 2.5 Inch
Revision = VDV1DP23
RemainingRatedWriteEndurance = 100 %
FailurePredicted = NO
PcieSSDBusId = 101
PcieSSDDeviceId = 0
PcieSSDFunctionId = 0
RAIDStatus = Ready
HotSpareStatus = No
AvailableRaidDiskSpace = 930.750 GB
FreeSizeInBytes = 930.75 GB
RaidType = Windows Software RAID
SasAddress = Not Applicable
WWN = 0x3b5cd8a65c06bfd6
Certified = Not Applicable
NonRAIDDiskCachePolicy = Not Applicable
OperationState = Not Applicable
140
RACADM Subcommand Details