CLI Guide

The following command creates a virtual disk:
racadm storage createvd:RAID.Integrated.1-1 -rl r0 -
pdkey:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
The following command starts an initialization operation on a specified virtual disk:
racadm storage init:Disk.Virtual.0:RAID.Integrated.1-1 -speed fast
The following command deletes the specified virtual disk:
racadm storage deletevd:Disk.Virtual.0:RAID.Integrated.1-1
The following command encrypts the specified virtual disk:
racadm storage encryptvd:Disk.Virtual.0:RAID.Integrated.1-1
NOTE: Virtual disk must be created with either SED or NVMe drives behind PERC.
The following command assigns Local Key Management (LKM) security key for controller:
racadm storage createsecuritykey:RAID.Integrated.1-1 -key <Key id> -xxx <passphrase>
The following command modifies Local Key Management (LKM) security key for controller:
racadm storage modifysecuritykey:RAID.Integrated.1-1 -key <Key id> -oldpasswd
<oldpassphrase> -newpasswd <newpassphrase>
The following command deletes Local Key Management (LKM) security key for controller:
racadm storage deletesecuritykey:RAID.Integrated.1-1
To convert the physical disk drive and assign hotspare.
The following command converts the specified nonstorage physical disk drive to a storage capable physical disk drive:
racadm storage converttoraid:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
The following command converts the specified physical disk drive to a nonstorage physical disk drive:
racadm storage
converttononraid:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
The following command assigns or unassigns a global or dedicated Hot spare:
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -
assign no
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -
assign yes -type ghs
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -
assign yes -type dhs -vdkey:Disk.Virtual.0:RAID.Integrated.1-1
The following command converts the specified nonstorage physical disk to a storage capable physical disk with windows
meta data
racadm storage converttoraid:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -
mdtype windows
To reset, clear, and import the storage configuration to the controller.
The following command imports the current foreign configuration from the controller:
racadm storage importconfig:RAID.Integrated.1-1
The following command deletes all virtual disks and unassigns hot spare from the associated controller:
racadm storage resetconfig:RAID.Integrated.1-1
RACADM Subcommand Details