Users Guide

Table Of Contents
Broadcom DRVLin-UG128-100
77
Emulex Drivers for Linux User Guide
1400 - Failed to update xri-sgl size and mapping: %d
Updatation of host els xri-sgl sizes and mappings failed.
Data: None
Severity: Error
LOG: LOG_MBOX | LOG_SLI
Action: None required.
1401: Failed to enable pci device.
Failed to enable PCI device during initialization.
Data: None
Severity: Error
Log: LOG_INIT
Action: None required.
1402: Failed to set up pci memory space.
PCI initialization failed.
Data: None
Severity: Error
Log: LOG_INIT
Action: None required.
1404: Failed to set up driver resource.
Driver resource initialization failed.
Data: None
Severity: Error
Log: LOG_INIT
Action: None required.
1405: Failed to initialize iocb list.
Driver resource initialization failed.
Data: None
Severity: Error
Log: LOG_INIT
Action: None required.
1406: Failed to set up driver resource.
Initialization failed to set up driver resource.
Data: None
Severity: Error
Log: LOG_INIT
Action: None required.
1407: Failed to create scsi host.
Initialization failed to create SCSI host.
Data: None
Severity: Error
Log: LOG_INIT
Action: None required.
Table 8: FC Error Log Messages and Their Descriptions (Continued)