Tx KB Count FC kilobytes transmitted by this FC function.
Tx Sequences – FC sequences transmitted by this FC function.
LIP CountThe number of LIP events that have occurred for the FC function. This field is not supported if the topology
is not arbitrated loop. Loop initialization consists of the following:
Temporarily suspending loop operations.
Determining whether loop-capable ports are connected to the loop.
Assigning AL_PA IDs.
Providing notification of configuration changes and loop failures.
Placing loop ports in the monitoring state.
Error Frames – The number of frames received with CRC errors.
Link Failures – The number of times the link has failed. A link failure is a possible cause of a timeout.
Loss of Signal – The number of times the signal was lost.
Invalid Tx Words – The total number of invalid words transmitted by this FC function.
Ex Count Orig The number of FC exchanges originating on this FC function (not supported on VMware ESXi servers
being managed through the CIM interface).
Active XRIs – The number of active XRIs (not supported on VMware-based ESXi platforms using the CIM interface).
Received P_BSY – The number of FC port-busy link response frames received.
Link Transitions – The number of times the SLI port sent a link attention condition.
Elastic Buf Overruns – The number of times the link interface has had its elastic buffer overrun.
Rx Frames – The number of FC frames received by this FC function.
Rx Words The number of FC words received by this FC function.
Rx KB Count – The received kilobyte count by this FC function.
Rx Sequences – The number of FC sequences received by this FC function (not supported on VMware ESXi servers
being managed through the CIM interface).
NOS Count – The number of NOS events that have occurred on the switched fabric. The NOS count is not supported
for Emulex Windows drivers or for arbitrated loop.
Dumped Frames – The number of frames that were lost because of a lack of host buffers available. This option is not
currently supported for the Storport Miniport driver or the driver for Solaris.
Loss of Sync – The number of times loss of synchronization has occurred.
Prim Seq Prot Errs – The Primitive Sequence Protocol error count. This counter is incremented whenever there is any
type of protocol error.
Invalid CRCs – The number of frames received that contain CRC failures.
Ex Count Resp – The number of FC exchange responses made by this FC function (not supported on VMware ESXi
servers being managed through the CIM interface).
Active RPIs – The number of RPIs (not supported on VMware ESXi servers being managed through the CIM
interface).
Receive F_BSY – The number of FC fabric-busy link response frames received.
Primitive Seq Timeouts The number of times a primitive sequence event timed out (not supported on VMware ESXi
servers being managed through the CIM interface).
Arbitration Timeouts – The number of times the arbitration loop has timed out. Large counts could indicate a
malfunction somewhere in the loop or heavy usage of the loop (not supported on VMware ESXi servers being managed
through the CIM interface).
If supported by the adapter, click Clear Counters to clear all the values displayed on the tab.