– Speed – The speed, or speeds, at which the selected port can run.
– OUI – The vendor’s OUI, also known as the IEEE Company Identifier for the vendor.
– Date – The vendor’s date code in MM/DD/YY format.
– Serial Number – The serial number provided by the vendor.
– Part Number – The part number provided by the SFP vendor.
– Revision – The vendor revision level.
Diagnostic Data area:
– Temperature – The internally measured module temperature.
– Supply Voltage – The internally measured supply voltage in the transceiver.
– TX Bias Current – The internally measured transmitted bias current.
– TX Output Power – The measured transmitted output power.
– RX Input Power – The measured received input power.
7.10 Viewing VPD Information
The VPD tab (Figure 32) displays vital product data (if available) for the selected adapter port, such as the product name,
part number, and serial number.
To view VPD information, perform these steps:
1. Select the Host or Fabric view.
2. In the discovery-tree, select the FC function whose VPD information you want to view.
3. Select the VPD tab.