Users Guide
Broadcom DRVLin-LPe-UG124-100
48
Emulex Drivers for Linux User Guide
0263: Discovery Mailbox error: state:
Either the driver could not allocate resources or it could not send sparam_mbox or cfglink_mbox.
Data: (1) address of sparam_mbox command (2) address of cfglink_mbox command
Severity: Error
Log: LOG_MBOX
Action: Attempt to unload and reload the driver when it is convenient.
0264: No NPIV Fabric support
The switch to which the port is connected does not support NPIV.
Data: None
Severity: Error
Log: LOG_ELS
Action: Check the switch configuration.
0266: Issue NameServer Req <cmdcode> err <rc> Data: <fc_flag> <fc_rscn_id_cnt>
The driver was unable to send the NameServer CT command.
Data: (1) vports fc_flag (2) vports fc_rscn_id_cnt
Severity: Error
Log: LOG_DISCOVERY
Action: Check the port and switch configurations.
0267: NameServer GFF Rsp <did> Error (<ulpStatus> <un.ulpWord[4]>) Data: <fc_flag> <fc_rscn_id_cnt>
The NameServer GFF CT request failed.
Data: (1) vports fc_flag (2) vports fc_rscn_id_cnt
Severity: Error
Log: LOG_DISCOVERY
Action: Check the port and switch configurations.
0268: NS cmd <cmdcode> Error (<ulpStatus> <un.ulpWord[4]>)
The NameServer CT request failed.
Data: None
Severity: Error
Log: LOG_DISCOVERY
Action: Check the port and switch configurations.
0271: Illegal State Transition: node <nlp_DID> event <evt>, state <nlp_state> Data: <nlp_rpi> <nlp_-
flag>
The current node state does not have a handler for this event.
Data: (1) nlp_rpi (2) nlp_flag
Severity: Error
Log: LOG_DISCOVERY
Action: Verify that all targets are still visible to the SCSI mid-layer.
0272: Illegal State Transition: node <nlp_DID> event <evt>, state <nlp_state> Data: <nlp_rpi> <nlp_-
flag>
The driver is completing a PLOGI but does not have the rcv_plogi flag set.
Data: (1) nlp_rpi (2) nlp_flag
Severity: Error
Log: LOG_DISCOVERY
Action: Verify that all targets are still visible to the SCSI midlayer.
Table 7: LPFC Error Log Messages and Their Descriptions (Continued)