Users Guide
Broadcom DRVLin-LPe-UG124-100
61
Emulex Drivers for Linux User Guide
0387:Failed to allocate an iocbq
Failed to get an IOCBQ from the list of available IOCBQs.
Data: None
Severity: Error
Log: LOG_SLI
Action: None required.
0388:Not a valid WCQE code: x<hex cqe_code>
The event code is invalid. This event will be dropped.
Data: None
Severity: Error
Log: LOG_SLI
Action: Ensure that the adapter firmware is current.
0391:Error during rpi post operation
The driver was trying to post pages to the firmware to keep target login information and encountered a failure.
Data: None
Severity: Error
Log: LOG_MBOX, LOG_SLI
Action: Unload and reload the driver.
0393:Error <rc> during rpi post operation
The driver was trying to post pages to the firmware to keep target login information and encountered a failure.
Data: None
Severity: Error
Log: LOG_MBOX, LOG_SLI
Action: Unload and reload the driver.
0394: Failed to allocate CQ_EVENT entry
The asynchronous event handler was unable to allocate an event queue entry to which to transfer the asynchronous event.
Data: None
Severity: Error
Log: LOG_MBOX, LOG_SLI
Action: This could be a V-LINK clear from the switch or a fatal error from the firmware. Perform a dump from the Emulex OneCommand
Manager application.
0395: The mboxq allocation failed
The asynchronous link event handler could not allocate a mailbox command to issue the READ_LA (read link attention) mailbox
command.
Data: None
Severity: Error
Log: LOG_SLI
Action: None required.
0396:The lpfc_dmabuf allocation failed
The asynchronous link event handler could not allocate a mailbox command to issue the READ_LA mailbox command.
Data: None
Severity: Error
Log: LOG_SLI
Action: None required.
Table 7: LPFC Error Log Messages and Their Descriptions (Continued)