Emulex Drivers for Linux User Guide
0705: Allocation request of <num> command buffers will exceed max of <hba_queue_depth>. Reducing
allocation request to <size>
The number of command buffers requested will exceed the maximum so a smaller quantity will be allocated.
Data: None
Severity: Warning
Log: LOG_FCP verbose
Action: None required.
0708: Allocation request of <num_to_alloc> command buffers did not succeed. Allocated <num_allocated>
buffers.
The allocation request for the specified command buffers did not succeed. However, the specified number of buffers are allocated.
Data: None
Severity: Warning
Log: LOG_FCP
Action: None required.
0711: detected queue full - lun queue depth adjusted to%d
The driver detected a queue full status on a SCSI command response. New LUN queue depth is reported.
Data: (1) New LUN queue depth
Severity: Warning
Log: LOG_FCP verbose
Action: This might indicate an oversubscribed target array. Check your SAN configuration and I/O workload.
0713: SCSI layer issued Device Reset (%d, %d)
A device reset was issued.
Data: None
Severity: Error
Log: LOG_FCP
Action: None required.
0714: SCSI layer issued bus reset
The SCSI layer is requesting the driver to abort all I/Os to all targets on this HBA.
Data: (1) ret
Severity: Error
Log: Always
Action: Check the state of the targets in question.
0720: FCP command <cmnd[0]> residual overrun error
A residual overrun error occurred while processing the specified FCP command.
Data: (1) request_bufflen (2) resid
Severity: Warning
Log: LOG_FCP verbose
Action: If this issue persists, check the targets for errors.
0721: Device Reset rport failure: rdata <rdata>
The reset of the R_Port failed.
Data: None
Severity: Error
Log: LOG_FCP
Action: None required.
Table 7: LPFC Error Log Messages and Their Descriptions (Continued)