Users Guide

Broadcom DRVLin-LPe-UG124-100
91
Emulex Drivers for Linux User Guide
1828: Vport Deleted
A Vport was deleted.
Data: None
Severity: Error
Log: LOG_VPORT verbose
Action: No action, informational.
1829: CT command failed to delete objects on fabric.
A command issued to the fabric to delete an associated resource for an object, such as for a port, failed.
Data: None
Severity: Error
Log: LOG_VPORT verbose
Action: Software driver error. If this issue persists, report these errors to Broadcom Technical Support.
1830: Signal aborted mbxCmd <command>
A pending mailbox command was aborted because the thread received a signal.
Data: None
Severity: Error
Log: LOG_VPORT verbose
Action: Retry the attempted command.
1831: Create VPORT Interrupted
The port creation process was unexpectedly interrupted at a critical time, and the operation was unsuccessful.
Data: None
Severity: Error
Log: LOG_VPORT verbose
Action: The process was interrupted while creating a vPort. Retry the command.
1832: No pending MBOX command to handle
Data: None
Severity: Error
Log: LOG_MBOX
Action: None required.
1835: Vport discovery quiesce failed: state <port_state> fc_flags <fc_flag> wait msecs <jiffies_to_m-
secs(jiffies - start_time)>
Could not pause discovery on this vPort.
Data: None
Severity: Error
Log: LOG_VPORT
Action: None required.
1836: Could not issue unreg_login(all_rpis) status <rc>
The unreg_login cannot be issued.
Data: None
Severity: Error
Log: LOG_MBOX, LOG_VPORT
Action: None required.
Table 7: LPFC Error Log Messages and Their Descriptions (Continued)