Users Guide

Broadcom NVMe-FC-120UG-100
18
Emulex NVMe over Fibre Channel User Guide
Example
hbacmd nvme-set-sstable 10:00:00:90:fa:5d:05:a9 50:06:01:60:90:20:5C:38 nqn.2014-
08.com.example:nvme.host.sys.xyz 0x0001 1 4096
Information similar to the following is displayed:
NVMe Subsystem table successfully updated for port 10:00:00:90:fa:5d:05:a9
4.2.2.2 The nvme-get-sstable Command
The nvme-get-sstable command allows you to retrieve the NVMe subsystem management table that is maintained for
each FC+NVMe port.
Syntax
hbacmd nvme-get-sstable <WWPN> [Target WWPN]
Parameters
Support Requirement
Mandatory
Example
hbacmd nvme-get-sstable 10:00:00:90:fa:5d:05:a9
Information similar to the following is displayed:
NVMe Qualified Name : nqn.2014-08.com.example1:nvme.host.sys.xyz
Port WWN : 50:06:01:60:90:20:5C:38
Node WWN : 50:06:01:60:10:20:5C:38
CtrlID : 0X0001
NVMe Qualified Name : nqn.2014-08.com.example2:nvme.host.sys.xyz
Port WWN : 50:06:01:60:90:20:5C:39
Node WWN : 50:06:01:60:10:20:5C:39
CtrlID : 0X0001
If an invalid Target WWPN is used, the following error message is displayed:
ERROR: The Subsystem table does not contain any entries for the specified initiator port.
ERROR: <823>: No subsystem entries were found for the specified initiator port.
4.2.2.3 The nvme-list Command
The nvme-list command lists the NVMe over FC subsystems recognized by the FC driver connected to the FC port. The
list contains all discovered subsystems, as well as those that were added to the subsystem table using the
nvme-set-sstable command.
Syntax
hbacmd nvme-list <WWPN> [Target WWPN]
Parameters
WWPN The WWPN of the FC initiator port.
Target WWPN The WWPN of an FC port on an NVMe-capable device (optional).
WWPN The WWPN of the FC initiator port.
Target WWPN The WWPN of an FC port on an NVMe-capable device (optional).