Users Guide
Table Of Contents
- Table of Contents
- Chapter 1: Introduction
- Chapter 2: Installation
- Chapter 3: Configuration
- 3.1 ESXi Command Line Tool Transition
- 3.2 FC Driver Configuration
- 3.2.1 Configuration Methods for FC Driver Parameters
- 3.2.2 Emulex ExpressLane Support
- 3.2.3 FC-SP-2 Authentication (DH-CHAP) Support
- 3.2.4 Trunking Support
- 3.2.5 Dynamically Adding LUNs
- 3.2.6 Dynamically Adding Targets
- 3.2.7 FC Driver Module Parameters
- 3.2.8 Creating an FC Remote Boot Disk
- 3.2.9 Managing Devices through the CIM Interface
- 3.2.10 Installing the Emulex CIM Provider
- 3.2.11 Creating, Deleting, and Displaying vPorts
- 3.2.12 Configuring VVols
- 3.2.13 Adjusting the LUN Queue Depth
- 3.3 Configuring NVMe over FC on a NetApp Target
- 3.4 Configuring NVMe over FC on an Initiator System
- Chapter 4: Troubleshooting the FC Driver
- Chapter 5: Troubleshooting the NVMe Driver
- Appendix A: esxcli Management Tool
- Appendix B: lpfc Driver BlockGuard Functionality
- Appendix C: Using the VMID Feature on a Brocade Switch
- Appendix D: Using the VMID Feature on a Cisco Switch
- Appendix E: NPIV Configuration
- Appendix F: License Notices
Broadcom DRVVM-UG128-100
70
Emulex Drivers for VMware ESXi User Guide
4667 Error reading Cgn Params
Unable to read congestion firmware parameters from adapter.
ACTION: No action required. If the issue persists, report the error to Broadcom Technical Support.
1431: Invalid HBA PCI-device group: <dev_grp>
An invalid adapter PCI-device group was detected.
ACTION: No action required.
8912 Async FC Trunking Event - Speed Logical speed: port0 <Link_status> port1 <link_status> port2
<link_status> port3 <link_status>
Trunked port link status update.
ACTION: No action required
8913 trunk error:<trunk_error> seen on port0: <Link_Status> port1:<Link_Status> port2:<Link_Status>
port3:<Link_Status> UNDEFINED. update driver
Trunk port setting error.
ACTION: If the issue persists, report the error to Broadcom Technical Support.
0150 Attempting reset to recover from UE
Driver in recovery phase from UE.
ACTION: No action required.
3190 Over Temperature: <Value> Celsius- Port Name <Value>
Display temperature above the threshold value.
ACTION: No action required. If the issue persists, report the error to Broadcom Technical Support.
0314 Failed to start lpfc_do_work World
Failed to create the world.
ACTION: The driver fails to load. Contact Broadcom Technical Support..
0529: Failed setup of slow-path mailbox CQ: rc = <value>
The driver failed to set up the completion queue. A failure code is reported.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
0475 Not configured for supporting MSI-X cfg_use_msi: <cfg_use_msi>.
The lpfc_use_msi module parameter should have been set to 2.
ACTION: Set module parameter lpfc_use_msi=2.
1814 Mbox <u.mb.mbxCommand> failed, no vport
The vPort field of this mailbox command was not completed.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
2527: Failed to allocate non-embedded SGE array.
The driver failed to allocate the non-embedded scatter/gather entry array.
ACTION: No action required.
2929: Resource Extent Opcode <value> is unsupported
Unsupported event code.
ACTION: No action required.