Users Guide
Table Of Contents
- Table of Contents
- Chapter 1: Introduction
- Chapter 2: Installation
- Chapter 3: Configuration
- 3.1 ESXi Command Line Tool Transition
- 3.2 FC Driver Configuration
- 3.2.1 Configuration Methods for FC Driver Parameters
- 3.2.2 Emulex ExpressLane Support
- 3.2.3 FC-SP-2 Authentication (DH-CHAP) Support
- 3.2.4 Trunking Support
- 3.2.5 Dynamically Adding LUNs
- 3.2.6 Dynamically Adding Targets
- 3.2.7 FC Driver Module Parameters
- 3.2.8 Creating an FC Remote Boot Disk
- 3.2.9 Managing Devices through the CIM Interface
- 3.2.10 Installing the Emulex CIM Provider
- 3.2.11 Creating, Deleting, and Displaying vPorts
- 3.2.12 Configuring VVols
- 3.2.13 Adjusting the LUN Queue Depth
- 3.3 Configuring NVMe over FC on a NetApp Target
- 3.4 Configuring NVMe over FC on an Initiator System
- Chapter 4: Troubleshooting the FC Driver
- Chapter 5: Troubleshooting the NVMe Driver
- Appendix A: esxcli Management Tool
- Appendix B: lpfc Driver BlockGuard Functionality
- Appendix C: Using the VMID Feature on a Brocade Switch
- Appendix D: Using the VMID Feature on a Cisco Switch
- Appendix E: NPIV Configuration
- Appendix F: License Notices
Broadcom DRVVM-UG128-100
87
Emulex Drivers for VMware ESXi User Guide
0370 Invalid completion queue type <type>
The event queue entry is not for a mailbox or a work queue entry.
ACTION: No action required.
3370 FW LOG mailbox completed with status <shdr_status> add_status <shdr_add_status>, mbx status
<mbxStatus>
Enabling firmware logging in host memory failed.
ACTION: No action required.
2752 KILL_BOARD command failed retval <retval>
The KILL_BOARD mailbox command is failed by the firmware.
ACTION: report the error to Broadcom Technical Support.
2022 INIT VPI Mailbox failed status <rc>, mbxStatus <lpfc_mqe_status>
The INIT VPI mailbox command has failed.
ACTION: No action required.
2751 Adapter failed to restart, status reg <status>, FW Data: A8 <offset_A8> AC <offset_AC>
The adapter initialization has failed.
ACTION: Try to reset the port. If this issue persists report the error to Broadcom Technical Support.
2515 ADD_FCF_RECORD mailbox failed with status <rc>
The mailbox command to add the FCF record has failed.
ACTION: No action required.
2510 RQ_DESTROY mailbox failed with status <shdr_status> add_status <shdr_add_status>, mbx status <rc>
The mailbox command sent to delete the work queue has failed.
ACTION: No action required.
2511 POST_SGL mailbox failed with status <shdr_status> add_status <shdr_add_status>, mbx status <rc>
The mailbox command sent to post the SGL pages to the firmware has failed.
ACTION: No action required.
0572 iotag <iotag> out of range, Max is <last_iotag>
The I/O tag in the completed IOCB is out of range.
ACTION: This error could indicate a software driver, firmware, or a hardware issue. Report the error to Broadcom Technical Support.
2513 POST_SGL_BLOCK mailbox command failed status <shdr_status> add_status <shdr_add_status> mbx
status <rc>
The mailbox command sent to post the SGL pages to the firmware has failed.
ACTION: No action required.
2860 SLI authentication is required for INIT_LINK but has not done yet
The INIT_LINK mailbox command has failed and the link may not be up.
ACTION: Report the error to Broadcom Technical Support.