Users Guide
Table Of Contents
- Table of Contents
- Chapter 1: Introduction
- Chapter 2: Booting from SAN
- Chapter 3: Updating and Enabling Boot Code
- Chapter 4: Emulex LightPulse FC BIOS utility
- 4.1 Navigating the Emulex LightPulse FC BIOS Utility
- 4.2 Starting the Emulex LightPulse FC BIOS Utility
- 4.3 Enabling an Adapter to BFS
- 4.4 Scanning for Target Devices
- 4.5 Configuring Boot Devices
- 4.6 Configuring Advanced Adapter Parameters
- 4.6.1 Changing the Default AL_PA
- 4.6.2 Changing the PLOGI Retry Timer
- 4.6.3 Enabling or Disabling the Spinup Delay
- 4.6.4 Setting Auto Scan
- 4.6.5 Enabling or Disabling EDD 3.0
- 4.6.6 Enabling or Disabling the Start Unit Command
- 4.6.7 Enabling or Disabling the Environment Variable
- 4.6.8 Enabling or Disabling Auto Boot Sector
- 4.7 Configuring Adapter Firmware Parameters
- 4.8 Resetting the Adapter to Default Values
- 4.9 Using Multipath BFS
- Chapter 5: OpenBoot
- Chapter 6: Configuring Boot Using the UEFI HII
- 6.1 Prerequisites
- 6.2 Starting the UEFI HII
- 6.3 Configuring Boot in the UEFI HII
- 6.4 Setting Boot from SAN
- 6.5 Scanning for Fibre Devices
- 6.6 Adding Boot Devices
- 6.7 Deleting Boot Devices
- 6.8 Changing the Boot Device Order
- 6.9 Configuring HBA and Boot Parameters
- 6.9.1 Changing the Topology
- 6.9.2 Changing the PLOGI Retry Timer
- 6.9.3 Changing the Link Speed
- 6.9.4 Changing the Maximum LUNs per Target
- 6.9.5 Changing the Boot Target Scan Method
- 6.9.6 Changing the Device Discovery Delay
- 6.9.7 Configuring the Brocade FA-PWWN
- 6.9.8 Configuring the Brocade Boot LUN
- 6.9.9 Configuring 16G Forward Error Correction
- 6.9.10 Selecting Trunking
- 6.10 Resetting Emulex Adapters to Their Default Values
- 6.11 Displaying Adapter Information
- 6.12 Legacy-Only Configuration Settings
- 6.13 Requesting a Reset or Reconnect
- 6.14 Emulex Firmware Update Utility
- 6.15 NVMe over FC Boot Settings
- 6.16 Enabling or Disabling the HPE Shared Memory Feature (HPE Systems Only)
- Chapter 7: Troubleshooting
Broadcom BT-FC-UG128-100
71
Emulex Boot for the Fibre Channel Protocol User Guide
6.9.1 Changing the Topology
NOTE: Point-to-point and FC-AL topologies are supported on the LPe31000-series, LPe32000-series, and LPe35000-
series adapters.
By default, the LPe12000-series and LPe16000-series adapters use auto topology with loop first. If you want to use a
topology other than the default, you must change the topology setting before configuring boot devices. For FC-AL, each
adapter has a default AL_PA of 01 (hexadecimal).
The topology options available in LPe12000-series and LPe16000-series adapters are shown in Figure 46.
You can configure these items:
Auto topology with loop first – default
Auto topology with point-to-point first
FC-AL
Point-to-point
The topology options available in LPe31000-series, LPe32000-series, and LPe35000-series adapters are shown in
Figure 47.
NOTE: FC-AL is private loop only (direct-attach).
Point-to-point
FC-AL
To select the adapter topology, perform these steps:
1. From the adapter list (Figure 31), select the adapter whose topology you want to change and press Enter.
2. From the main configuration menu (Figure 32), select Configure HBA and Boot Parameters and press Enter.
3. In the Configure HBA and Boot Parameters window, navigate to Topology Selection and press Enter.
Information similar to Figure 46 or Figure 47 is displayed.