Users Guide
Table Of Contents
- Table of Contents
- Chapter 1: Introduction
- Chapter 2: Booting from SAN
- Chapter 3: Updating and Enabling Boot Code
- Chapter 4: Emulex LightPulse FC BIOS utility
- 4.1 Navigating the Emulex LightPulse FC BIOS Utility
- 4.2 Starting the Emulex LightPulse FC BIOS Utility
- 4.3 Enabling an Adapter to BFS
- 4.4 Scanning for Target Devices
- 4.5 Configuring Boot Devices
- 4.6 Configuring Advanced Adapter Parameters
- 4.6.1 Changing the Default AL_PA
- 4.6.2 Changing the PLOGI Retry Timer
- 4.6.3 Enabling or Disabling the Spinup Delay
- 4.6.4 Setting Auto Scan
- 4.6.5 Enabling or Disabling EDD 3.0
- 4.6.6 Enabling or Disabling the Start Unit Command
- 4.6.7 Enabling or Disabling the Environment Variable
- 4.6.8 Enabling or Disabling Auto Boot Sector
- 4.7 Configuring Adapter Firmware Parameters
- 4.8 Resetting the Adapter to Default Values
- 4.9 Using Multipath BFS
- Chapter 5: OpenBoot
- Chapter 6: Configuring Boot Using the UEFI HII
- 6.1 Prerequisites
- 6.2 Starting the UEFI HII
- 6.3 Configuring Boot in the UEFI HII
- 6.4 Setting Boot from SAN
- 6.5 Scanning for Fibre Devices
- 6.6 Adding Boot Devices
- 6.7 Deleting Boot Devices
- 6.8 Changing the Boot Device Order
- 6.9 Configuring HBA and Boot Parameters
- 6.9.1 Changing the Topology
- 6.9.2 Changing the PLOGI Retry Timer
- 6.9.3 Changing the Link Speed
- 6.9.4 Changing the Maximum LUNs per Target
- 6.9.5 Changing the Boot Target Scan Method
- 6.9.6 Changing the Device Discovery Delay
- 6.9.7 Configuring the Brocade FA-PWWN
- 6.9.8 Configuring the Brocade Boot LUN
- 6.9.9 Configuring 16G Forward Error Correction
- 6.9.10 Selecting Trunking
- 6.10 Resetting Emulex Adapters to Their Default Values
- 6.11 Displaying Adapter Information
- 6.12 Legacy-Only Configuration Settings
- 6.13 Requesting a Reset or Reconnect
- 6.14 Emulex Firmware Update Utility
- 6.15 NVMe over FC Boot Settings
- 6.16 Enabling or Disabling the HPE Shared Memory Feature (HPE Systems Only)
- Chapter 7: Troubleshooting
Broadcom BT-FC-UG128-100
87
Emulex Boot for the Fibre Channel Protocol User Guide
6.10 Resetting Emulex Adapters to Their Default Values
NOTE: The following information pertains to resetting default values:
The reconnect feature is not applicable while configuring the Brocade FA-PWWN, configuring the Brocade Boot
LUN, and selecting trunking, as all these procedures require a system reboot.
Resetting the adapter to its default settings clears all entries made while configuring the boot device, as detailed
in Section 4.5, Configuring Boot Devices.
A system reboot is required after resetting an adapter to its default values.
Resetting the system defaults also clears the NVRAM target list and sets all FC and NVMe boot devices to 0.
Default settings are listed in Table 7.
Table 7: BootCode Defaults
Parameter Default Valid Values
Boot from SAN Disabled Enabled
Disabled
Topology Auto Topology: Loop First (for
LPe12000-series adapters)
Auto Topology: Loop First (for
LPe16000-series adapters
Point-to-point (for
LPe31000-series, LPe32000-
series, and LPe35000-series
adapters)
Auto Topology: Loop First (default)
Auto Topology: Point-to-Point First
FC-AL
Point-to-Point
PLOGI Retry Timer Disabled
Disabled
50 ms
100 ms
200 ms
Link Speed (Auto negotiate) Auto negotiate (the adapter speed is selected
automatically based on its model).
2Gb/s
4Gb/s
8Gb/s
16Gb/s
32Gb/s
Max LUNs Setting 256 0 to 4096
Delay Device Discovery 0000 0000 to 0255
Brocade FA-PWWN Disabled
Enabled
Disabled
Brocade Boot LUN Disabled Enabled
Disabled
16G Forward Error Correction Enabled
Enabled
Disabled
Emulex NVMe Boot Settings Disabled
Enabled
Disabled
Trunking Disabled
4-Lane Trunk
2-Lane Trunk