Developers Guide

Importing PS Series Windows Server volumes
53 Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import | 3041-BP-EM
6.2 Offline import process PS Series
Perform the following steps to import data from a PS Series volume to an SC Series array in offline mode:
1. Open the Dell Storage Client and select Log in to a Storage Center or Data Collector.
Note: The Dell Storage Client can connect to a Dell Storage Manager Data Collector or connect directly to an
SC Series array. Both options are supported with the Thin Import process. The instructions in this section
focus only on connecting directly to an SC Series array. Thin Import requires Dell Storage Client/Dell Storage
Manager Data Collector version 2015 R2.
2. Log in to the Dell Storage Client with administrative credentials.
3. Click the Storage tab.
4. Navigate to Fault Domains > iSCSI. Select the iSCSI fault domain to be used for the import process.
Note: On systems with more than one iSCSI fault domain, select a fault domain that is configured on the
same network as the PS Series array.