White Papers
12 Version 1.3.0
7 Implementation Description
339
This section describes the requirements and guidelines for implementing RAID profile.
340
Table 2 shows the instances of CIM Elements for this profile. Instances of the CIM Elements shall be
341
implemented as described in Table 2.
342
Table 2 – CIM Elements: RAID Profile
343
Element Name
Requirement
Description
Classes
DCIM_RAIDService
Mandatory
See section 7.3
DCIM_ControllerView
Mandatory
See section 7.1.1
DCIM_EnclosureView
Mandatory
See section 7.1.2
DCIM_VirtualDiskView
Mandatory
See section 7.1.3
DCIM_PhysicalDiskView
Mandatory
See section 7.1.4
DCIM_ControllerBatteryView
Mandatory
See section 7.1.5
DCIM_EnclosureEMMView
Mandatory
See section 7.1.6
DCIM_EnclosurePSUView
Mandatory
See section 7.1.7
DCIM_EnclosureFanSensor
Mandatory
See section 7.1.8
DCIM_EnclosureTemperatureSensor
Mandatory
See section 7.1.9
DCIM_RAIDEnumeration
Mandatory
See section 7.2.1
DCIM_RAIDString
Mandatory
See section 7.2.2
DCIM_RAIDInteger
Mandatory
See section 7.2.3
DCIM_LCElementConformsToProfile
Mandatory
See section 7.4
DCIM_LCRegisteredProfile
Mandatory
See section 7.4
Indications
None defined in this profile
344
7.1 View Classes
345
The view classes represent the properties and status of the storage devices. The FQDD property
346
correlates the view to a specific device such as RAID.Integrated.1-1 for an integrated RAID controller..
347
7.1.1 Controller View - DCIM_ControllerView
348
This section describes the implementation for the DCIM_ControllerView class. This class shall be
349
instantiated in the Implementation Namespace: root/dcim.
350
7.1.1.1 Resource URIs for WinRM
®
351
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-
352
schema/2/DCIM_ControllerView?__cimnamespace=root/dcim”
353
The key property shall be the InstanceID.
354