White Papers

Version 1.2.0 29
Table 18– DCIM_EnclosureFanSensor - Properties 500
Property Name Requirement Type Additional Requirements
SystemCreationClassName Mandatory String
The property value shall be
DCIM_ComputerSytem”.
SystemName Mandatory String
The property value shall be
DCIM:ComputerSystem
CreationClassName Mandatory String
The property value shall be
DCIM_EnclosureFanSensor
DeviceID Mandatory String
The property shall have the
sensor FQDD value.
FQDD Mandatory String
The property shall represent Fully
Qualified Device Description
(FQDD)
BaseUnits Mandatory uint16
The property value shall be 19
(RPM).
CurrentReading Mandatory sint32
The present value indicated by
the sensor. The property value
shall be in rpm.
ElementName Mandatory String
The property shall describe the
sensor location.
PrimaryStatus Mandatory uint32
The property shall represent the
status of the device and shall be
one of the following values:
0 - Unknown
1 - OK
2 - Degraded
3 - Error
RateUnits Mandatory uint16
The property value shall be 4.
(Per Minute)
SensorType Mandatory Uint16
The property value shall be 5.
(Tachometer)
UnitModifier Mandatory sint32
The property shall have the value
0 denoting that the
CurrentReading property value
need not be multiplied by the
UnitModifier property value.
SettableThresholds[] Mandatory uint16
An array representing the writable
thresholds supported by sensor.
The property shall be NULL
because this sensor is a read-only
sensor.
SupportedThresholds[] Mandatory uint16 The array property shall be NULL.
UpperThresholdCritical Mandatory sint32 The array property shall be NULL.
UpperThresholdNonCritical Mandatory sint32 The array property shall be NULL.
LowerThresholdCritical Mandatory sint32 The array property shall be NULL.
LowerThresholdNonCritical Mandatory sint32 The array property shall be NULL.
501