Property Name Requirement Type Additional Requirements
shall be in Degrees C.
ElementName Mandatory string
The property shall describe the
sensor location.
PrimaryStatus Mandatory uint32
The property shall represent the
status of the device and shall be
one of the following values:
0 - Unknown
1 - OK
2 - Degraded
3 - Error
RateUnits Mandatory uint16
The property value shall be 0
(None).
SensorType Mandatory Uint16
The property value shall be 2
(Temperature).
UnitModifier Mandatory sint32
The property shall have the value
0 denoting that the
CurrentReading property value
need not be multiplied by the
UnitModifier property value.
SettableThresholds[] Mandatory uint16
An array representing the writable
thresholds supported by Sensor.
The property shall be “null” value
since this is read-only sensor
SupportedThresholds[] Mandatory uint16
The array property shall have
following values:
0 -
LowerThresholdNonCritical
1 -
UpperThresholdNonCritical
2 - LowerThresholdCritical
3 - UpperThresholdCritical
UpperThresholdCritical Mandatory sint32
The property shall have upper
critical threshold value in Degree
Centigrade.
UpperThresholdNonCritical Mandatory sint32
The property shall have upper
non-critical threshold value in
Degree Centigrade.
LowerThresholdCritical Mandatory sint32
The property shall have lower
critical threshold value in Degree
Centigrade.
LowerThresholdNonCritical Mandatory sint32
The property shall have lower
non-critical threshold value in
Degree Centigrade.
525
7.2 Attributes 526
This section details the supported attributes for the storage devices. Not all attributes shall be available 527
depending on the controller model. Each attribute is separate instance of the attribute class. The FQDD 528