White Papers

14 Version 1.4.0
Property Name
Requirements
Type
Requirement and Description
ChassisName
Mandatory
string
The property shall be “Main System Chassis”
for monolithic and “Server Blade” for
modular’s server blades.
ChassisServiceTag
Optional
string
This property represents the service tag for
the modular enclosure chassis.
This property shall be represented for modular
server blades.
ChassisSystemHeight
Mandatory
uint16
The property shall be in U of rack space units.
The property shall be applicable only for
monolithic server.
CMCIP
Optional
string
This property represents the IP address for
the modular enclosure chassis management
controller (CMC).
This property shall be represented for modular
server blades.
CPLDVersion
Mandatory
string
The property shall represent the CPLD
version.
CPURollupStatus
Mandatory
uint32
The property shall contain the rollup status of
all the CPUs and shall contain one of the
following values:
0(Unknown)
1(OK)
2(Degraded)
3(Error).
CPURollupStatus provides a high level status
value, intended to align with Red-Yellow-
Green type representation of status.
ExpressServiceCode
Mandatory
String
ExpressServiceCode of the system.
FanRollupStatus
Mandatory
uint32
The property shall contain the fan rollup status
of all the system components and shall
contain one of the following values:
0(Unknown)
1(OK)
2(Degraded)
3(Error).
FanRollupStatus provides a high level status
value, intended to align with Red-Yellow-
Green type representation of status.
HostName
Mandatory
string
System name string in ASCII.
LicensingRollupStatus
Mandatory
uint32
The property shall contain the licensing rollup
status of all the system components and shall
contain one of the following values:
0(Unknown)
1(OK)
2(Degraded)
3(Error).
LicensingRollupStatus provides a high level
status value, intended to align with Red-
Yellow-Green type representation of status.