Version 1.2.0 11
7.1.2 Operations 263
The following table lists the operations implemented on DCIM_SystemView. 264
Table 3 – DCIM_SystemView – Operations 265
Operation Name
Requirements
Required Input
Get
Mandatory
Instance URI
Enumerate
Mandatory
Class URI
266
7.1.3 Properties 267
The following table details the implemented properties for DCIM_SystemView instance that represents 268
the host system. The “Requirements” column shall denote whether the property is implemented (for 269
requirement definitions, see section 3). The Additional Requirements” column shall denote either 270
possible values for the property, or requirements on the value formulation. 271
Table 4 – DCIM_SystemViewProperties 272
Requirements
Type
Requirement and Description
Mandatory
string
The property shall be “System.Embedded.1
Mandatory
string
The property shall be “System.Embedded.1
Mandatory
string
Asset tag of the system.
Optional
string
The property represents the modular chassis
slot numbers that the server blade occupies in
the modular enclosure.
This property shall be represented for modular
server blades.
Mandatory
uint32
The property shall contain the battery rollup
status of all the system components and shall
contain one of the following values:
0(Unknown)
1(OK)
2(Degraded)
3(Error).
BatteryRollupStatus provides a high level
status value, intended to align with Red-
Yellow-Green type representation of status.
Mandatory
string
String number of the BIOS release date. The
date string, if supplied, is in mm/dd/yyyy
format.
Mandatory
string
System BIOS version.