White Papers

12 Version 1.2.0
Requirements
Type
Requirement and Description
Optional
uint16
The property shall represent the geometric
dimension of the server blade enclosure in
modular enclosure described. The property
shall have one of the following values:
0 - "Single width, single height"
1 - "Dual width, single height",
2 - "Single width, dual height",
3 - "Dual width, dual height",
4 - "Not Applicable"
This property shall be represented for modular
server blades.
Mandatory
string
The property shall represent the motherboard
part number.
Mandatory
string
The property shall represent the motherboard
serial number.
Mandatory
string
The property shall be “Main System Chassis”
for monolithic and “Server Blade” for
modular’s server blades.
Optional
string
This property represents the service tag for
the modular enclosure chassis.
This property shall be represented for modular
server blades.
Mandatory
uint16
The property shall be in U of rack space units.
The property shall be applicable only for
monolithic server.
Optional
string
This property represents the IP address for
the modular enclosure chassis management
controller (CMC).
This property shall be represented for modular
server blades.
Mandatory
string
The property shall represent the CPLD
version.
Mandatory
uint32
The property shall contain the rollup status of
all the CPUs and shall contain one of the
following values:
0(Unknown)
1(OK)
2(Degraded)
3(Error).
CPURollupStatus provides a high level status
value, intended to align with Red-Yellow-
Green type representation of status.
Mandatory
string
ExpressServiceCode of the system.