Administrator Guide

Technical support and resources
10 Telemetry Streaming with iDRAC9 Storage Reports | ID 430
2.4 Workflow Examples
Configuration of the Storage reports could be done with either of interface racadm/redfish/SCP.
Example:
racadm>>set idrac.telemetry.EnableTelemetry Enabled
[Key=idrac.Embedded.1#Telemetry.1]
Object value modified successfully
racadm>>set idrac.TelemetryNVMeSMARTData.1.EnableTelemetry Enabled
[Key=idrac.Embedded.1#TelemetryNVMeSMARTData.1]
Object value modified successfully
After the above configuration, NVMeSMARTData Report can be pulled, or streamed through http
subscription, remote syslog or server-side events (SSE) based methods, Further details of the configuration
could be found in the Telemetry Getting Started whitepaper.
Similarly, other storage reports can be configured and streamed to assess the health and state of the drives
on the server.
Below examples are from servers having multiple SSD’s and Smart drives. The metrics of the Storage reports
visualized below for example, could be used get the insight of the drive temperatures, drive states, drive
lifetime, and so on.