Administrator Guide

Technical support and resources
6 Telemetry Streaming with iDRAC9 Storage Reports | ID 430
2 Telemetry Storage Metric Reports
The health state of the SSD drives behind PERC storage controller can be assessed with the telemetry metric
report named “StorageDiskSmartData”. And similarly, the health state of the PCIeSSD devices which are not
controlled by SWRAID controller, can be derived with the telemetry metric report named “NVMeSMARTData”.
The temperature information of storage devices can be found from the telemetry metric report named
“StorageSensor”.
Below are the Telemetry storage metric reports supported in iDRAC 4.00 release:
StorageDiskSMARTData: PERC SSD disk smart information
NVMeSMARTData: PCIeSSD/NVMe device smart information
StorageSensor: Temperature reading for internal server storage devices
Telemetry storage metric reports
Telemetry Storage
Reports
Metrics Description
StorageDiskSMARTData
CRCErrorCount,CommandTimeout,CurrentPendingS
ectorCount,DriveTemperature,ECCERate,EraseFail
Count,ExceptionModeStatus,MediaWriteCount,Perce
ntDriveLifeRemaining,PowerCycleCount,PowerOnHo
urs,ProgramFailCount,ReadErrorRate,ReallocatedBl
ockCount,UncorrectableErrorCount,UncorrectableLB
ACount,UnusedReservedBlockCount,UsedReserved
BlockCount,VolatileMemoryBackupSourceFailures
SSD SMART information.
NVMeSMARTData
AvailableSpare,AvailableSpareThreshold,Composite
Temparature,ControllerBusyTimeLower,ControllerBu
syTimeUpper,CriticalWarning,DataUnitsReadLower,
DataUnitsReadUpper,DataUnitsWrittenLower,DataU
nitsWrittenUpper,HostReadCommandsLower,HostR
eadCommandsUpper,HostWriteCommandsLower,Ho
stWriteCommandsUpper,MediaDataIntegrityErrorsLo
wer,MediaDataIntegrityErrorsUpper,NumOfErrorInfo
LogEntriesLower,NumOfErrorInfoLogEntriesUpper,P
ercentageUsed,PowerCyclesLower,PowerCyclesUpp
er,PowerOnHoursLower,PowerOnHoursUpper,Unsaf
eShutdownsLower,UnsafeShutdownsUpper
PCIeSSD/NVMe device
smart information.
StorageSensor
TemperatureReading
Temperature information
for server storage internal
devices.