FAQ

Configure iDRAC alerts for Redfish events
8 Manage iDRAC alerts by using the Redfish Eventing feature in YX3X and later PowerEdge servers
2 Configure iDRAC alerts for Redfish events
2.1 Enable iDRAC alerts
To enable the Redfish Event Service, set the “ServiceEnabled” property in the EventService URI
(/redfish/v1/EventService) to Enabled, which in turn enables the iDRAC alerts.
Operation: HTTP PATCH
URI: https://<iDRAC -IP>/redfish/v1/EventService
Schema: https://redfish.dmtf.org/schemas/v1/EventService.xml
Enable iDRAC alerts for Redfish events
2.2 Configure the category of iDRAC alerts for Redfish events
iDRAC alerts can be configured through SCP (Server Configuration Profile). For more information, see the
Using Server Configuration Profiles to Deploy Operating Systems to Dell EMC PowerEdge Servers on the
support site. For information about framing payload, see http://ftp.dell.com/manuals/common/dellemc-server-
config-profile-refguide.pdf.