Dell EqualLogic FS7600 Series Appliances Hardware Owner's Manual
© Copyright 2011–2013 Dell Inc. All rights reserved. Dell™ and EqualLogic® are trademarks of Dell Inc. All trademarks and registered trademarks mentioned herein are the property of their respective owners. Information in this document is subject to change without notice. Reproduction in any manner whatsoever without the written permission of Dell is strictly forbidden.
Table of Contents Preface 1 Basic Appliance Information Appliance Components Connecting an Appliance to Power Turning Power On and Off Required Tools Technical Specifications 2 Replacing Components Safety Recommendations Required Tools Using an Electrostatic Wrist Strap Replacing a Controller Installing a Controller Replacing a Power Supply Replacing a Cooling Fan Replacing the Appliance Returning Failed Hardware 3 What to Do Next Appendix A: NOM Information (Mexico Only) Glossary v 1 1 4 5 6 6 9 9 9 9
Dell EqualLogic FS7600 Hardware Owner's Manual iv
Preface Dell™ EqualLogic® FS Series appliances, coupled with PS Series arrays, offer a high-performance, highavailability, scalable NAS solution. This manual describes how to maintain and troubleshoot the customerreplaceable components of the EqualLogic FS7600 appliance. Audience The information in this guide is intended for hardware administrators responsible for maintaining EqualLogic FS7600 hardware.
Dell EqualLogic FS7600 Hardware Owner's Manual Preface Note, Caution, and Warning Symbols A NOTE symbol indicates important information that helps you make better use of your hardware or software. A CAUTION symbol indicates potential damage to hardware or loss of data if instructions are not followed. A WARNING symbol indicates a potential for property damage, personal injury, or death.
1 Basic Appliance Information This chapter contains information about the location and basic operation of the components in a Dell™ EqualLogic® FS7600 NAS appliance. This document also includes general operating procedures such as power ON and power OFF operations, and how to return failed components. Appliance Components The only customer-replaceable components in the appliance are the bezel and the fans, on the front of the appliance, and the controllers and power supplies, on the back of the appliance.
Dell EqualLogic FS7600 Hardware Owner's Manual LED Indicator Icon 1 Basic Appliance Information State and Description Power-On Indicator The power LED lights green when at least one power supply is connected to a power source and is supplying power to the system. System Identification Button Identification buttons on the front and back panels locate a particular system within a rack.
Dell EqualLogic FS7600 Hardware Owner's Manual 1 Basic Appliance Information Table 3: FS7600 Back-Panel Components Number Component 1 2 3 4 5 6 7 8 9 10 Service tag Displays the appliance service tag information (identical to the service tag information on the front panel).
Dell EqualLogic FS7600 Hardware Owner's Manual LED Indicator/ Button Controller Health Indicator System Identification Button Cache Active/OffLoad LED Icon 1 Basic Appliance Information State and Description Solid green—The controller is clustered and fully functional. Alternating blinking amber/green—The expected hardware configuration does not match the actual hardware. Unlit—Controller is in power OFF mode. Indicates health of the controller. Solid blue—Normal operation.
Dell EqualLogic FS7600 Hardware Owner's Manual 1 Basic Appliance Information Figure 4: Secure the Power Cable with the Strain Relief The appliance turns on as soon as the power supplies are connected to a live power source. Each controller contains a backup power supply (BPS). The BPS batteries begin to charge when the appliance is connected to power. A full charge takes up to eight hours to complete; the NAS appliance is not fully redundant until the battery is fully charged.
Dell EqualLogic FS7600 Hardware Owner's Manual 1 Basic Appliance Information Turning Controller Power Off If you need to replace a controller, turn off the power to start a shutdown. Use a small, thin tool such as a #1 Phillips screwdriver to press and release the power LED button on the back of the controller you plan to remove. See Figure 5.
Dell EqualLogic FS7600 Hardware Owner's Manual 1 Basic Appliance Information 90 VAC to 264 VAC, autoranging, 47 Hz/63 Hz Voltage This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V. Battery Power Supply Battery 12.8 V to 13.2 V, 4.8 Ah to 6 Ah, 63 Wh to 77 Wh Physical Height Width Depth Weight (maximum configuration) Weight (empty) 86.4 mm (3.4 in.) 481.5 mm (18.96 in.)—with rack flange 446.3 mm (17.6 in.)—without rack flange 813.
Dell EqualLogic FS7600 Hardware Owner's Manual 8 1 Basic Appliance Information
2 Replacing Components This chapter describes how to replace appliance components or the entire appliance. Safety Recommendations Follow these safety recommendations: • Before you work on the EqualLogic FS7600 hardware, read and follow the safety instructions packaged with your system. • Use care when moving and opening the shipping box. Leave the components packaged until you are ready to install them.
Dell EqualLogic FS7600 Hardware Owner's Manual 2 Replacing Components Figure 6: Using an Electrostatic Wrist Strap 2. Fit the band tightly around your wrist. 3. Connect the banana plug to ground, or attach the plug to the alligator clip and connect the clip to a grounded device such as an ESD mat or the metal frame of a grounded piece of equipment. Replacing a Controller If a controller fails, you can replace it while the appliance is online. Many repairs require a Dell-certified service technician.
Dell EqualLogic FS7600 Hardware Owner's Manual 2 Replacing Components Figure 7: Removing a Controller 6. Pull the handle down and out. See callouts 2, 3, and 4 in Figure 7. 7. Support the controller with two hands, and place it on an antistatic surface. Installing a Controller 1. Correctly orient the controller with the handle on top. 2. Push the controller into the slot until you feel resistance. See callout 1 in Figure 8. Figure 8: Installing a Controller 3.
Dell EqualLogic FS7600 Hardware Owner's Manual 2 Replacing Components The controller powers on automatically, which can take several minutes. (For LED states during power-on, see Appliance Back-Panel Features on page 2). After the controller is powered on, reattach the controller through the Group Manager GUI or CLI. For information, see the Dell EqualLogic Group Manager Administrator's Manual. Installing an SFP+ Tranceiver 1. Position the transceiver so that its key is oriented correctly to the port. 2.
Dell EqualLogic FS7600 Hardware Owner's Manual 2 Replacing Components 2. Connect the power cord to the power supply, then connect the other end to the power source. 3. Secure the cord with the strain relief strap. 4. Make sure the power supply LED illuminates. Figure 10: Installing a Power Supply When installing a new power supply, allow several seconds for the system to recognize the power supply and determine its status.
Dell EqualLogic FS7600 Hardware Owner's Manual 2 Replacing Components Figure 11: Removing the Bezel Attaching the Bezel To attach the bezel, see Figure 12 and follow these steps: 1. Insert the right side of the bezel into the slot on the right side of the chassis (callout 1). 2. Push the bezel toward the left side and engage the bezel with the left side of the chassis (callout 2). 3. Use the key to lock the bezel (callout 3).
Dell EqualLogic FS7600 Hardware Owner's Manual 2 Replacing Components Replacing a Cooling Fan The FS7600 NAS appliance contains six hot-swappable cooling fans. If one fan fails, you can replace it while the appliance remains online. To maintain proper cooling while the system is on, replace only one fan at a time. The procedure for replacing each fan is identical. In the event of a problem with a particular fan, the fan number is referenced by the system’s management software.
Dell EqualLogic FS7600 Hardware Owner's Manual 2 Replacing Components 3. Press the fan release tabs (Figure 14 callout 1) and pull the cooling fan out of the NAS appliance chassis (callout 2). Figure 14: Removing a Cooling Fan Installing a Fan 1. Align the plug at the base of the cooling fan with the connector on the system board. 2. Slide the cooling fan (Figure 15 callout 2) into the securing slots until the tabs (callout 1) lock into place. Figure 15: Installing a Cooling Fan 3.
Dell EqualLogic FS7600 Hardware Owner's Manual 2 Replacing Components Replacing the Appliance If the entire NAS appliance fails, you must replace it. You will not have a functioning NAS cluster until the appliance is replaced and configured, unless you have other NAS hardware providing the services. Removing the appliance will cause the entire NAS cluster to be lost, requiring you to rebuild the NAS cluster from scratch.
Dell EqualLogic FS7600 Hardware Owner's Manual 18 2 Replacing Components
3 What to Do Next You can customize the NAS cluster and create additional containers, CIFS shares, and NFS exports. You can also use snapshots to protect NAS container data. NAS Cluster Documentation The Dell EqualLogic Group Manager Administrator's Manual provides detailed NAS cluster information. The Group Manager online help describes how to use the Group Manager graphical user interface (GUI) to manage a NAS cluster.
Dell EqualLogic FS7600 Hardware Owner's Manual 20 3 What to Do Next
Appendix A: NOM Information (Mexico Only) The information provided in Table 7 applies to the device described in this document in compliance with the requirements of the official Mexican standards (NOM). Table 7: NOM Information for Mexico Norma Oficial Mexicana Importer Model number: E02T Dell México S.A. de C.V. Paseo de la Reforma 2620 -- 11° Piso Col. Lomas Altas 11950 México, D.F. Supply voltage: 100–240 VAC Frequency: 50/60 Hz Current consumption: 10–6.
Dell EqualLogic FS7600 Hardware Owner's Manual 22 Appendix A: NOM Information (Mexico Only)
Glossary NAS cluster Understanding terminology related to a NAS cluster will help you successfully deploy, manage, and maintain your unified storage environment. Provides highly available and scalable NAS storage by using a PS Series group and at least one EqualLogic NAS appliance, configured and managed through Group Manager. Dell FluidFS High-performance, scalable file system that is configured on storage space. group See PS Series group.
Glossary: – 24
Index A appliance I installation dimensions 7 front and back panels 1-2 specifications 6 weight 7 safety precautions 9 L LEDs B back-panel features 2 back-panel LEDs 3 backup power supply (BPS) 3, 5 bezel attaching 14 key lock on controller 14 removing 13 back panel 3 controller 5 front panel 1 N NAS cluster documentation 19 post-configuration tasks 19 C controller location on back panel 3 cooling fan P power turning on the controller 5 power supply unit (PSU) 3 see fan 15 R E electrostatic di
Index: appliance – Group Manager GUI 26