Voltage
90 VAC to 264 VAC, autoranging, 47 Hz/63 Hz
This system is also designed to be connected to IT power systems with a phase to
phase voltage not exceeding 230 V.
Battery Power Supply
Battery 12.8 V to 13.2 V, 4.8 Ah to 6 Ah, 63 Wh to 77 Wh
Physical
Height 86.4 mm (3.4 in.)
Width
481.5 mm (18.96 in.)—with rack flange
446.3 mm (17.6 in.)—without rack flange
Depth
813.0 mm (32.0 in.)—with bezel and handle
741.0 mm (29.2 in.)—without bezel and handle
Weight (maximum
configuration)
30.5 kg (67 lb.)
Weight (empty) 12.86 kg (28.36 lb.)
Environmental
Operating temperature
Continuous operation: 5°C to 40°C (41°F to 104°F) with a maximum temperature
gradation of 20°C (68°F) per hour
Storage temperature
40°C to 60°C (–40°F to 140°F) with a maximum temperature gradation of 20°C per
hour
Operational relative
humidity
20% to 80% (non-condensing) with maximum humidity gradation of 10% per hour at
maximum wet bulb temperature of 29°C (89°F)
Storage relative
humidity
5% to 95% with a maximum humidity gradation of 10% per hour at a maximum wet
bulb temperature of 38°C (100°F)
Maximum operational
vibration
0.26 Grms (5 Hz – 350 Hz @ 0.0002G2/Hz) in operational orientation for 5 minutes
Maximum storage
vibration
1.88 Grms with the following PSD profile (all 6 sides tested for 15 minutes each side)
Frequency (Hz) G2/Hz
10 0.13
20 0.13
70 0.004
130 0.004
165 0.0018
500 0.0018
Maximum operational
shock
31G half-sine shock +/-5% with pulse duration of 2.6 ms +/-10% in the operational
orientation
Maximum storage
shock
Square wave shock of 27G, at 235 inches/second (596.90 cm/second) velocity
change (all six sides tested)
Operating altitude
-15.2 mto 3048 m (-50 to 10,000 feet)
For altitudes above 2950 feet, the maximum operating temperature is derated 1°F/550
feet.
Storage altitude –15.2 m to 10,668 m (–50 ft to 35,000 ft)
Airborne Contaminant
Level Class
G1 as defined by ISA-S71.04-1985
7