Setup Guide

PS Series 3000 QuickStart Step 1. Set Up the Array Hardware
13
Array locator (upper
left)
Off No power or normal condition.
Flashing orange Administrator enabled the array locator function.
Warning condition
(lower left)
Off No power or normal condition.
Flashing orange One or more of the following has occurred:
RAID set is degraded but still functioning.
RAID set (volume level) has lost blocks.
Component temperature is near a limit.
Fan has failed or RPMs exceed opper or
lower limit.
Power supply is not installed or has no power.
Only one control module installed or control
module has failed over.
Active control module syncing with
secondary.
No communication between control modules.
No replication progress for more then 1 hour.
Installed spare disk does not have enough
capacity to replace a disk in a RAID set.
A non-critical hardware component failed.
Error condition
(lower right)
Off No power or normal condition.
Flashing orange One or more of the following has occurred:
RAID is not functioning.
Lost block table is full.
Temperature exceeds upper or lower limit.
Control module cache has lost data.
One or both fan trays are not installed.
Both fans on a fan tray have failed.
Cache battery has less than 72 hours of charge
or temperature is too high to charge battery.
NVRAM coin cell battery has failed.
Cache contains data that does not belong to
any of the installed disks.
More than one valid RAID set exists in array.
Control modules are different models.
A critical hardware component has failed.
Operations panel failed or not installed.
Storage enclosure processor that monitors
array components has experienced a failure.
Operations Panel LED Descriptions (Continued)
Operations LEDs Color Description