PS3000 Series Hardware Maintenance Basic Array Information
1–5
Serial line characteristics are as follows:
- 9600 baud
-One STOP bit
- No parity
- 8 data bits
- No hardware flow control
2. Log in to an account with read-write access, such as the
grpadmin account.
3. Enter the
shutdown command, as shown next.
If you are using a serial connection to shut down an array, it is safe to turn off
power when the “press any key” message appears. (Pressing any key will restart
both control modules.)
If you are using a network connection, the session will be disconnected before the
array is fully shut down. Confirm that the ACT LED on each control module is off
(not lit) before turning off power to the array.
After performing array maintenance, you can turn on power to the array. When the
array restart completes, the member and volumes will be set online.
Login: grpadmin
Password: xxxxxxx
Welcome to Group Manager
Copyright 2001-2007 EqualLogic, Inc.
> shutdown