Install Guide

PS6210 Install and Setup Guide
3 Connecting the Array Cables
Connect and Secure the Power Cables
Obtainthepowercablesthatwereshippedwiththearray.Ifthearraywasnotshippedwithpowercables,
contactyourPSSeriessupportproviderorresellerforpowercableinformation.
Note: Thepowersupplyandcoolingmodulesaredifferentforthe2Uandthe4Uarraymodels.However,they
functionthesamewayintermsofintegrationintoadatacenterpowerinfrastructure.
1. MakesurethatthepowerswitchisintheOFF(O)positionbeforeconnectingthepowercables.
2. ConnectthepowercablestothepowersuppliesasshowninFigure6andFigure7.
3. Securethepowercablestothesystem:
a. Securethepowercablesfirmlytothebracketnexttothesystempowerreceptacleusingthe
providedhook-and-loopstrap.
b. Makesurethestrapistightlyboundtothebracketanchorpoint(removeanyslack).
c. Biasthepowercabletowardthestrapandwrapthestraptightlyaroundthecableagainstthe
shoulderofthepowercableconnector.
4. Attachthepowercablestoapowersource:
Plugthepowercablesintoagroundedelectricaloutletoraseparatepowersourcesuchasanunin-
terruptedpowersupply(UPS)orapowerdistributionunit(PDU).ThebottomLEDofthepowersupply
willbeilluminatedgreen(indicatingpowerispresent)whenpowercablesareconnected.
EachUPS(notincluded)shouldbeonadifferentcircuitandmustprovidethecorrecttypeofvoltagefor
anadequateamountoftime.
Alternately,connectonepowersupplyandcoolingmoduletoaUPSsystemandconnecttheothermod-
uletoadifferentsourceofpower.
Caution: Donotturnonpowertothearrayyet.
11