Install Guide

PS6210 Install and Setup Guide
4 Software Configuration
Ifyouusedthesetuputilitytocreateorexpandagroup,oraddedthearraytoanexistinggroupwiththeRemote
Setupwizard,youmustsettheRAIDpolicyforthegroupmember.
UseeithertheGroupManagercommandlineinterface(CLI)orthegraphicaluserinterface(GUI)tosetthe
RAIDpolicy.
Using the CLI to Set the RAID Policy
TousetheGroupManagerCLItosettheRAIDpolicyforanewgroupmember:
1. Logintothegroup,ifyouarenotalreadyloggedin.(Afterthesetuputilitycompletes,youwillstillbe
loggedintothegroup.)Useoneofthefollowingmethodstoconnecttothegroup:
Serialconnectiontoamember.SeeSet Up a Serial Connection to the Array on page 14.
TelnetorsshconnectiontothegroupIPaddress.
2. Attheloginprompt,enterthegrpadminaccountnameandthepasswordthatyouspecifiedwhencreatingthe
group.
3. AttheGroupManagercommandprompt,enterthefollowingcommandtospecifyRAID6,orRAID6-
accelerated(availableXSarraymodelsonly),RAID10,orRAID50forthepolicyvariable:
member select member_name raid-policy policy
Forexample,thefollowingcommandconfiguresmember1withRAID6:
member select member1 raid-policy raid6
Using the Group Manager GUI to Set the RAID Policy
ForthelatestinformationonbrowsersupportfortheGroupManagerGUI,seethePSSeriesRelease Notes.
AfteryouaddamembertoaPSSeriesgroup,youmustsettheRAIDpolicyforthememberandchoosethe
storagepool.ThestorageinthememberisavailableafteryousettheRAIDpolicy.
TousetheGUItosettheRAIDpolicyforamembers,usethefollowingprocedure:
Procedure
1. ClickGroupandthenclickthegroupnametoopentheGroupSummarywindow.
2. ExpandMembersandthendouble-clickthemembername.TheGUIshowswhetheramemberisconfigured
ornot.
3. ClickYesinthewarningdialogboxtoopentheConfigureMember–GeneralSettingsdialogbox.
4. SelectthepoolandclickNext.Ifprompted,confirmyouwanttoassignthemembertothepool.
5. SelecttheRAIDpolicyontheConfigureMember–RAIDConfigurationdialogbox.
6. (Optional)SelectWait until the member storage initialization completes.
7. ClickNext.
8. ClickFinishintheConfigureMember–Summarydialogbox.
Note: AfterinitialRAIDconfiguration,ittakesafewminutesforGroupManagertodisplaythetotalusable
capacity.GroupManagermightshowasmalleramountuntiltheprocessiscomplete.
21