Administrator Guide

Table Of Contents
For information about replacing channel cards, see the Hardware Owner's Manual for your array model or contact your PS Series
support provider.
NVRAM Battery Status
Table 60. NVRAM Battery Status describes status values for control module NVRAM coin cell batteries and provides solutions for
any problems.
NOTE: Some arrays do not have an NVRAM battery.
Table 60. NVRAM Battery Status
Status Description Solution
good
Battery installed and fully charged None needed; informational.
bad
Battery failure Contact your PS Series support provider.
not-present
Battery is not installed
unknown
Battery status is not known
Monitor Disk Drives
Make sure you detect and replace failed drives as soon as possible. Although spare disks and RAID protect data against drive failures,
multiple failures might put data in jeopardy.
1. Click Group.
2. Expand Members and select the member name.
3. Click the Disks tab.
The Disk Array Summary panel shows the drives in the member. The number and type of drives shown depends on your array model.
The Installed Disks panel shows more information about each drive, including the slot, type, model and revision, size, status, and
errors. Closely monitor drives with errors.
CAUTION: Never pull out and then immediately reinsert a drive.
Disk Drive Status
Table 61. Disk Drive Status describes status values for drives and provides solutions for any problems.
NOTE: When you remove a drive from an array, Dell recommends that you not reinsert it immediately. Instead, wait for
the system to recognize that the drive is missing before reinserting it.
Table 61. Disk Drive Status
Status Description Solution
small
Drive is smaller than other drives in the member.
The drive cannot be used in the member.
Replace the drive with one that is the same
capacity or greater than the installed drives.
failed
Drive failure Contact your PS Series support provider for
information about replacing failed drives.
foreign label
Drive has a foreign label. The drive was probably
removed from a dierent array and then installed in
this array.
To use the drive, click foreign disk and clear the
label.
history of
failures
Previously failed drive Contact your PS Series support provider. To use
the drive, click history of failure and agree to use
the drive.
online
Drive is functioning. None needed; informational
About Monitoring
329