Users Guide

Table Of Contents
Collection{exchange_collection}
You can obtain the collection name from the ASM/ME GUI Collections node by browsing an individual collections
properties.
Alternatively, use the following command to display of all Collection names:
> ASMCLI list collections showobjectid
When you specify an objectID= parameter, the command parser ignores any subsequent volume=, collection=,
and component= parameters.
offpeak
Used with: smart, verify subcommands
Specify the offpeak parameter to schedule Checksum Verification during the offpeak Global Verification times
(predicted periods of low computer use). When you specify offpeak, you must also specify the checksum parameter.
You can specify that this parameter can be used with the smart command if you specify either checksum or verify, or
both.
You can also specify the offpeak parameter with the verify command.
If you do not specify either the offpeak parameter or the remote parameter, Checksum Verification begins
immediately after Smart Copy completion.
promoteandverify
Used with: smart subcommand
Specify promoteandverify to perform Checksum Verification directly on a promoted Exchange replica which will
pause replication until the operation has completed.
readwrite
Used with: mount subcommand
Specify the readwrite parameter to enable both reads from and writes to the mounted volume. If not specified, the
volume is mounted readonly.
recovery
Used with: smart subcommand
Specify recovery to perform Checksum Verification or Soft Recovery (or both) on the Smart Copy. You can
use this command only when making copies of Exchange objects.
You can specify the recovery subcommand together with the checksum subcommand option to perform both
operations simultaneously. If you do not specify either the smart or s subcommands, the recovery parameter is
ignored.
retry= n
Used with: mount, unmount, restore subcommands
Specify the retry= parameter with an integer value indicating the number of times to retry the operation if unsuccessful.
remote
Used with: smart, verify subcommands
Specify the remote parameter to schedule Checksum Verification on a remote computer instead of the local
computer. If configured on the remote computer, Checksum Verification (and Soft Recovery, if specified), runs during the
offpeak Global Verification times. Configure the remote computer to find and verify the newlycreated backup document.
You can specify that this parameter can be used with the smart command if you specify either checksum or verify or
both.
You can also specify the remote parameter with the verify command.
112
Using the Command Line Interface