Administrator Guide

Table Of Contents
Field Description
Name Name of the NAS controller (prexed with the NAS cluster name)
Service tag NAS controller service tag containing a unique identication number
Peer controller Peer for the selected NAS controller. NAS controllers are congured in pairs to ensure that
failure does not occur at a single point. The peer NAS controller name is prexed by the
NAS cluster name.
NAS Members Panel
Table 389. NAS Members Panel
Field Description
Total NAS members Number of NAS members dened for the NAS cluster
NAS member Name of the NAS controller. The NAS controller name is prexed with the NAS cluster
name.
Service tag Unique identication number used to identify the NAS controller
Status Status of the NAS controller:
Online — The NAS member is up and communicating with the cluster.
Oine — The NAS member has been taken oine.
Detached — The NAS member has been removed from the cluster.
Unknown — The cluster cannot communicate with the NAS member.
Model NAS controller model
Firmware version Firmware version running on the NAS controller
Peer controller Peer NAS controller for the selected NAS controller. NAS controllers are congured in pairs
to ensure that no single point of failure can occur. The peer NAS controller name is prexed
by the NAS cluster name.
NOTE: When you are using the CLI, the NAS controller name might look dierent because it is not prexed with the
cluster name.
NAS Power Supplies Panel
The Power Supplies panel displays the status of power supplies in an FS7500 controller or an FS7600/FS7610 appliance.
Table 390. Power Supplies Panel
Field Description
Status Status of the power supply. The status can be:
OK — The power supply is working within the valid operating range. A green
checkmark indicates an OK status.
Problem — The power supply is operating outside the valid operating range. A red
circle indicates a problem with the power supply.
Reference: GUI Panels, Wizards, and Dialog Boxes